2023
DOI: 10.1002/mp.16196
|View full text |Cite
|
Sign up to set email alerts
|

Monte Carlo‐derived 99mTc uptake quantification with commercial planar MBI: Absolute tumor activity

Abstract: Background: Molecular breast imaging (MBI) of 99m Tc-sestamibi is an emerging adjunct qualitative tool in the detection and diagnosis of breast cancer. Purpose: This work outlines the development and performance evaluation of a methodology to absolutely quantify tumor 99m Tc activity uptake using a commercially available dual-headed MBI system by implementing corrections for background, scatter, attenuation, and detector characteristics. Methods: A validated Monte Carlo application of a commercial MBI system w… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
2

Relationship

2
0

Authors

Journals

citations
Cited by 2 publications
(11 citation statements)
references
References 15 publications
0
11
0
Order By: Relevance
“…15 Our work demonstrates the feasibility of extending these BPU measurements to also include absolute normal tissue uptake estimates. Additional investigations will be needed to first properly implement this technique in patient images, where parenchymal uptake is not homogeneous and background ROIs throughout the same breast can differ in average pixel counts by up to 35%, 6 and to then determine correlation, if any, between absolute normal tissue activity concentrations to BPU classes and breast cancer risk.…”
Section: Discussionmentioning
confidence: 99%
See 4 more Smart Citations
“…15 Our work demonstrates the feasibility of extending these BPU measurements to also include absolute normal tissue uptake estimates. Additional investigations will be needed to first properly implement this technique in patient images, where parenchymal uptake is not homogeneous and background ROIs throughout the same breast can differ in average pixel counts by up to 35%, 6 and to then determine correlation, if any, between absolute normal tissue activity concentrations to BPU classes and breast cancer risk.…”
Section: Discussionmentioning
confidence: 99%
“…The simulated data set used to compare tumor activity metrics in this study consisted of both spherical and ellipsoid tumors in "hot" breast tissue. All simulations consisted of 10-min acquisitions of clinically-observed breast compressed thicknesses (b z = 4, 6, 8, 10, 12 cm), normal tissue uptake concentrations (C b = 10, 20, 60 nCi/cm 3 ), tumor diameters (d = 1.0, 1.5, 2.0, 2.5, 3.0 cm), 6 In all acquisitions, the detector heads were placed immediately adjacent to the simulated breast (Figure 1). Ellipsoid tumors were only simulated within the b z = 8 cm breast.…”
Section: Simulation Overviewmentioning
confidence: 99%
See 3 more Smart Citations