1997
DOI: 10.1118/1.598142
|View full text |Cite
|
Sign up to set email alerts
|

Monte Carlo calculation of dose rate distributions around wires

Abstract: Monte Carlo calculations of absolute dose rate in liquid water are presented in the form of away-along tables for 1 and 5 cm 192Ir wires of 0.3 mm diameter. Simulated absolute dose rate values can be used as benchmark data to verify the calculation results of treatment planning systems or directly as input data for treatment planning. Best fit value of attenuation coefficient suitable for use in Sievert-integrals-type calculations has been derived based on Monte Carlo calculation results. For the treatment pla… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

5
58
0
2

Year Published

2009
2009
2023
2023

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 59 publications
(65 citation statements)
references
References 21 publications
(22 reference statements)
5
58
0
2
Order By: Relevance
“…Monte Carlo dosimetry studies have been done (Angelopoulos et al 2000;Ballester et al 1997;Ballester et al 2001) for Ir-192 HDR brachytherapy sources. We modeled the Ir-192 HDR source (Fig.…”
Section: Radiation Sourcementioning
confidence: 99%
“…Monte Carlo dosimetry studies have been done (Angelopoulos et al 2000;Ballester et al 1997;Ballester et al 2001) for Ir-192 HDR brachytherapy sources. We modeled the Ir-192 HDR source (Fig.…”
Section: Radiation Sourcementioning
confidence: 99%
“…The ‫ء‬ F8 energy deposition tally was used to score the absorbed dose and the forced collision variance reduction technique was used to increase the number of charged particles in the vicinity of the scoring regions. 24 While the F6 collision kerma tally has been shown to be equivalent to absorbed dose from 192 Ir sources at distances beyond the first few millimeters, 28,29 the F6 collision kerma tally is not appropriate near the surface or at material boundaries where charged particle equilibrium does not exist.…”
Section: Methodsmentioning
confidence: 99%
“…These scoring voxels/cells assure volume averaging artifacts <0.1% for distances greater than 5 mm from the source. [18] The scored energy in water was converted to air kerma by multiplication of the ratio of mass attenuation coefficients of air and water. Air attenuation and scattering was corrected with the factor 1.012.…”
Section: Methodsmentioning
confidence: 99%