2010
DOI: 10.1016/j.chroma.2009.10.072
|View full text |Cite
|
Sign up to set email alerts
|

Monolithic methacrylate packed 96-tips for high throughput bioanalysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
14
0
1

Year Published

2011
2011
2015
2015

Publication Types

Select...
8

Relationship

4
4

Authors

Journals

citations
Cited by 40 publications
(15 citation statements)
references
References 37 publications
0
14
0
1
Order By: Relevance
“…The advantages of the developed phases include easy preparation and control of permeability and surface charge. monolith phases, frits are not necessary and often result in greater pH stability [18].…”
Section: Introductionmentioning
confidence: 99%
“…The advantages of the developed phases include easy preparation and control of permeability and surface charge. monolith phases, frits are not necessary and often result in greater pH stability [18].…”
Section: Introductionmentioning
confidence: 99%
“…As a result, it possesses very good permeability and high surface area. Based on the attractive character, monoliths were also used as the extractive media in some extractive technologies such as SPE [22,23], in-tube SPE [24,25], solid-phase microextraction [26] and SBSE [27]. In our previous study, a serial of new coatings based on Xiaojia Huang Linli Chen Fuhua Lin Dongxing Yuan monoliths for SBSE [27][28][29][30][31][32][33][34][35][36] have been prepared and applied to extract organic pollutants [27][28][29][30][31][32][33][34][35] and inorganic ions [36] in all kinds of matrices.…”
Section: Introductionmentioning
confidence: 99%
“…7,11,[19][20][21][22][23]31,37 2·4 Other flow through equilibrium microextraction techniques Some variations of dynamic flow through equilibrium SPME are based on the configuration of the extraction device, such as a microsyringe (syringe SPME) (Fig. 1E) and pipette tip (in-tip SPME) 47,51,52 (Fig. 1F).…”
Section: ·3 In-tube Spme Techniquesmentioning
confidence: 99%
“…Furthermore, the in-tip SPME can simultaneously handle 96 samples within 2 min in commercially available systems that use a 96-well format furnished with polymer monolithic tips and a robot. 51,115 Using tips developed in-house, a packed 96-tip assembly was used to successfully extract drugs in human plasma 115 and vitamin D3 in serum. 116 Local anesthetics, anticancer drugs, and β-blockers in human plasma could be also successfully detected by this tip extraction coupled with LC-MS/MS.…”
Section: ·1 Multi-well High-throughput Samplingmentioning
confidence: 99%