The platform will undergo maintenance on Sep 14 at about 7:45 AM EST and will be unavailable for approximately 2 hours.
1978
DOI: 10.1021/es60143a003
|View full text |Cite
|
Sign up to set email alerts
|

Monitoring of polynuclear aromatic hydrocarbons in water. II. Extraction and recovery of six representative compounds with polyurethane foams

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
10
0
1

Year Published

1980
1980
2002
2002

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 48 publications
(11 citation statements)
references
References 5 publications
0
10
0
1
Order By: Relevance
“…The number of samples ranged from 630 (naphthalene) to 926 (fluoranthene); the percentage of samples in which these PAHs were detected ranged from 1.0 (benzo[g,h,i]perylene) to 5.0 (phenanthrene) and 7.0 (naphthalene). andSaxena (1978a) reported concentrations of selected PAHs in surface waters used as drinking water sources in four U.S. cities (Huntington, West Virginia; Buffalo, New York; and Pittsburgh and Philadelphia, Pennsylvania). Total concentrations of PAHs ranged from 4.7 ng/L in Buffalo to 600 ng/L in Pittsburgh.…”
mentioning
confidence: 99%
“…The number of samples ranged from 630 (naphthalene) to 926 (fluoranthene); the percentage of samples in which these PAHs were detected ranged from 1.0 (benzo[g,h,i]perylene) to 5.0 (phenanthrene) and 7.0 (naphthalene). andSaxena (1978a) reported concentrations of selected PAHs in surface waters used as drinking water sources in four U.S. cities (Huntington, West Virginia; Buffalo, New York; and Pittsburgh and Philadelphia, Pennsylvania). Total concentrations of PAHs ranged from 4.7 ng/L in Buffalo to 600 ng/L in Pittsburgh.…”
mentioning
confidence: 99%
“…Various solvents have been proposed for desorption of compounds from PUF: acetone, 11,107,110,117,152 hexane, 107,133,134,153 methanol, 117 an acetone ± hexane mixture, 133 diethyl ether and petroleum ether. 121 Solvent desorption is carried out in the Sohxlet apparatus for 18 ± 24 h. 107, 113, 115, 116, 118, 130, 132 ± 134, 149 In some cases, samples are treated with ultrasound to intensify the process.…”
Section: Chromatographic Methodsmentioning
confidence: 99%
“…Traces of PAH are collected from water samples having large volumes (4 ± 60 litres) using columns filled with one or several cylindrical inserts of PUF (45645 mm). 109,110 A water sample heated to 62 AE 2 8C is passed through a column at a flow rate of 250 AE 10 ml min 71 . It was noted that pre-heating decreases the loss of PAH caused by co-precipitation on the suspended particles present in water samples.…”
Section: Chromatographic Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Os processos mais comumente empregados para esta finalidade são a extração líquido-líquido 41,42 e a troca iônica, em geral envolvendo sorventes sólidos/resinas de troca iônica [43][44][45][46][47] . Contudo, são conhecidas as vantagens e as limitações que tais procedimentos possuem quanto ao seu emprego 42,47 .…”
Section: Pré-concentração Em Ambiente Micelar Empregando a Metodologiunclassified