Monitoring dioxins and furans near an old municipal solid waste incinerator: Temporal variation in vegetation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2001
2001
2018
2018

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 18 publications
(5 citation statements)
references
References 25 publications
0
5
0
Order By: Relevance
“…Samples were prepared by grinding them with a cutting mill to a fine powder, and then placing them in a Soxhlet thimble. A mixture of the following 13 HRGC/HRMS analysis was carried using a Fisons CE 8000 GC coupled with a VG Autospec Ultima system (EI and multiple ion detection mode, resolution 10000). Two GC columns were used: DB 5-MS for hepta-and octaCDD and CDF, and CP-Sil 88 for tetra-through hexaCDD and CDF, including the 2,3,7,8-substituted isomers.…”
Section: Analytical Proceduresmentioning
confidence: 99%
See 1 more Smart Citation
“…Samples were prepared by grinding them with a cutting mill to a fine powder, and then placing them in a Soxhlet thimble. A mixture of the following 13 HRGC/HRMS analysis was carried using a Fisons CE 8000 GC coupled with a VG Autospec Ultima system (EI and multiple ion detection mode, resolution 10000). Two GC columns were used: DB 5-MS for hepta-and octaCDD and CDF, and CP-Sil 88 for tetra-through hexaCDD and CDF, including the 2,3,7,8-substituted isomers.…”
Section: Analytical Proceduresmentioning
confidence: 99%
“…While soils reflect cumulative PCDD/F deposition during rather longer periods of time, the PCDD/F levels in the vegetation can be a more suitable indicator of the atmospheric PCDD/F emissions over short periods of time. [11][12][13] In March 1998, 1999 and 2000, soil and herbage samples were collected and the concentrations of PCDD/F analyzed. [14][15][16] After the introduction of the technical improvements in the facility and during the period 1999-2000, a notable reduction (30%) was found in the levels of PCDD/Fs in the herbage samples.…”
Section: Introductionmentioning
confidence: 99%
“…Atmospheric deposition may be the main source of PCDD/F pollution for rice grain growing in mud. However, radishes are more likely to take up PCDD/Fs from the soil, as has been found for other root vegetables (Schuhmacher et al, 1997;Domingo et al, 1999). Homologue patterns for mud do not resemble those for soil, re#ecting mixed exposures from uptake mechanisms and atmospheric deposition.…”
Section: Discussionmentioning
confidence: 89%
“…Moreover, PCDD/F emissions from the HWI do not mean additional significant risks for the health of the individuals living in the vicinity of the facility. In recent years, we have performed various studies concerning the environmental impact and human health risks near several waste incinerators of Catalonia (Schuhmacher et al 1998b;Domingo et al 1999;Nadal et al 2002b;Ferré-Huguet et al 2006;Schuhmacher and Domingo 2006). We found that those incinerators whose emission M. Mari et al levels of PCDD/Fs, compared with those regulated by the European Union, did not constitute in general terms any relevant source of PCDD/Fs.…”
Section: Human Health Risksmentioning
confidence: 92%
“…In turn, vegetation receives inputs of airborne PCDD/Fs via gas phase and particulate dry matter as well as wet deposition (Meneses et al 2002). Concentrations of PCDD/Fs in vegetation are a more suitable indicator of the atmospheric emissions of contaminants during short periods of time (Domingo et al 1999(Domingo et al , 2002c.…”
Section: Introductionmentioning