2010
DOI: 10.1109/tia.2010.2041084
|View full text |Cite
|
Sign up to set email alerts
|

Modular High-Power Shunt-Interleaved Drive System: A Realization up to 35 MW for Oil and Gas Applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
14
0

Year Published

2011
2011
2024
2024

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 58 publications
(14 citation statements)
references
References 5 publications
0
14
0
Order By: Relevance
“…Using the double integral Fourier analysis method [17], the output ac harmonic currents cancellation effect of interleaving for a system of N parallel three-phase VSCs has theoretically been confirmed [13]. The impact of the non-conventional interleaving is also discussed in [15,18,19] and used in [16]. In summary, the previous work discussed above mainly focuses on symmetric interleaving and the impact of interleaving on system harmonic voltages and currents.…”
Section: Principle Of Asymmetric Interleavingmentioning
confidence: 84%
See 1 more Smart Citation
“…Using the double integral Fourier analysis method [17], the output ac harmonic currents cancellation effect of interleaving for a system of N parallel three-phase VSCs has theoretically been confirmed [13]. The impact of the non-conventional interleaving is also discussed in [15,18,19] and used in [16]. In summary, the previous work discussed above mainly focuses on symmetric interleaving and the impact of interleaving on system harmonic voltages and currents.…”
Section: Principle Of Asymmetric Interleavingmentioning
confidence: 84%
“…For example, it is very difficult to study the impact of interleaving on the circulating current and the relationship between the harmonic currents reduction, especially if more than two VSCs are involved in the paralleling system. Recently, people started to study the impact of interleaving on a paralleled three-phase VSC system in frequency domain [13,14,15,16]. Using the double integral Fourier analysis method [17], the output ac harmonic currents cancellation effect of interleaving for a system of N parallel three-phase VSCs has theoretically been confirmed [13].…”
Section: Principle Of Asymmetric Interleavingmentioning
confidence: 99%
“…For such interleaved-paralleling concepts, the circulating current between the paralleled threads could be significant [22] [23]. It appears as additional current ripples on the converter, which increase the current and thermal stress of the converters.…”
Section: B Interleaved-paralleling Of Two Convertersmentioning
confidence: 99%
“…This arrangement not only saves the cost but also makes the regulation of DC link voltage easier. However, the circulating current may occur due to the informality in switching instants and difference in parameters of paralleled inverters [6][7].…”
Section: Introductionmentioning
confidence: 99%