1978
DOI: 10.1016/0003-2697(78)90350-0
|View full text |Cite
|
Sign up to set email alerts
|

Modified Ellman procedure for assay of cholinesterases in crude enzymatic preparations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
86
0

Year Published

1995
1995
2020
2020

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 209 publications
(89 citation statements)
references
References 3 publications
1
86
0
Order By: Relevance
“…The procedure used for the determination of AchE activity in the heart was a modification of the method of Ellman et al (1961) as described by Gorun et al (1978). The principle of the method is the measurement of the thiocholine produced as acetylthiocholine is hydrolyzed.…”
Section: Determination Of Enzyme Activitiesmentioning
confidence: 99%
“…The procedure used for the determination of AchE activity in the heart was a modification of the method of Ellman et al (1961) as described by Gorun et al (1978). The principle of the method is the measurement of the thiocholine produced as acetylthiocholine is hydrolyzed.…”
Section: Determination Of Enzyme Activitiesmentioning
confidence: 99%
“…The plate could not be dried absolutely otherwise the enzyme could be inactivated. However, ethanol should be removed because it might inhibit acetylcholinesterase activity [5]. The TLC plate was put in a closed vessel containing a little water for humidity whereas plate should not contact with water directly.…”
Section: Modified Tlc Bioautographic Assaymentioning
confidence: 99%
“…Ellman's method is a classical method in detecting acetylcholinesterase inhibitors [4,5]. However, the results will be uncertain when testing colored samples or hydrophobic samples.…”
Section: Introductionmentioning
confidence: 99%
“…The blood in non-heparinized tubes was centrifuged at 3000 rpm for 20 min for other biochemical parameters. Cholinesterase activity was determined according to Ellman Method (28) as modified by Gorun et al (29) . The liver parameters [Alanine aminotrasferase (ALT), Aspartate aminotrasferase (AST), alkaline phosphates (ALP), total protein and albumin], kidney parameters (urea and creatinine), lipid profile (cholesterol, triglycerides) and antioxidant parameters [Catalase (CAT) and Glutathione-S-Transfrase (GST)] were determined by using local kits (from Biodiagonostic Company in Egypt).…”
Section: Toxicological Studiesmentioning
confidence: 99%