Modern Size‐Exclusion Liquid Chromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
254
0
2

Year Published

2010
2010
2023
2023

Publication Types

Select...
5
3
1

Relationship

1
8

Authors

Journals

citations
Cited by 439 publications
(257 citation statements)
references
References 0 publications
1
254
0
2
Order By: Relevance
“…PSS standards were used for calibration for system 1-3, PS for systems 4-8, pullulan for system 9 and for PEG system 10 calibration. In universal calibration the logarithm of the molecular weight of standards is not plotted on the vertical axis of the SEC calibration curve, but the logarithm of the product of the molecular weight and the intrinsic viscosity [14]. This product is sometimes referred to as the hydrodynamic volume.…”
Section: Ms-qp or A Tof-ms Was Used For Detectionmentioning
confidence: 99%
“…PSS standards were used for calibration for system 1-3, PS for systems 4-8, pullulan for system 9 and for PEG system 10 calibration. In universal calibration the logarithm of the molecular weight of standards is not plotted on the vertical axis of the SEC calibration curve, but the logarithm of the product of the molecular weight and the intrinsic viscosity [14]. This product is sometimes referred to as the hydrodynamic volume.…”
Section: Ms-qp or A Tof-ms Was Used For Detectionmentioning
confidence: 99%
“…In SEC, the separation mechanism is based on molecular hydrodynamic volume. The majority of polymers are soluble in organic or aqueous solvents at ambient temperature and SEC experiments are conducted at ambient or slightly increased temperatures [5,6,80].…”
Section: Size Exclusion Chromatographymentioning
confidence: 99%
“…Typically, polyolefins are dissolved at temperatures between 130 and 160 C. To prevent degradation, stabilizers and antioxidants are added to the solvent. The most common solvents for polyolefin fractionations are 1,2,4-trichlorobenzene (TCB), 1,2-dichlorobenzene, decaline, and in some cases cyclohexane [5,6].…”
Section: Introductionmentioning
confidence: 99%
“…[23] A triple detector GPC system, which consists of the combination of the sizebased separation by GPC with a light scattering detector (LS), a capillary viscometer and a concentration detector, allows the accurate determination of MMD, and also the study of the polymer molecular architecture. [24][25][26][27] Variation in the Mark-Houwink (MH) plot (log-log plot of intrinsic viscosity against molar mass), and in the related conformation plot (log-log plot of radius of gyration against molar mass), in correlation with SCB or comonomer content in polyethylene (PE) have been described in literature, [28,29] basically as a decrease in the intercept value with increasing SCB level. Application of MH plot to show chemical composition variations in P-E copolymers has also been demonstrated.…”
Section: Introductionmentioning
confidence: 99%