1989
DOI: 10.1016/0168-1176(89)80031-x
|View full text |Cite
|
Sign up to set email alerts
|

Models for mass-independent space and energy focusing in time-of-flight mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
14
0

Year Published

1993
1993
2015
2015

Publication Types

Select...
4
3
1

Relationship

1
7

Authors

Journals

citations
Cited by 40 publications
(14 citation statements)
references
References 9 publications
0
14
0
Order By: Relevance
“…No change in hardware is required whereas a similar approach to improve mass resolution in TOF/MS, employing dynamic post-source acceleration, is accomplished using an additional short-range dynamic field region. 5 The approach proposed here may provide higher mass resolution in the MALDI-TOF technique. The only necessary parameter for each specific TOF instrument is the geometric parameter η 0 = 2d/L, where d and L are the lengths of ion source and field-free drift tube.…”
Section: Discussionmentioning
confidence: 98%
“…No change in hardware is required whereas a similar approach to improve mass resolution in TOF/MS, employing dynamic post-source acceleration, is accomplished using an additional short-range dynamic field region. 5 The approach proposed here may provide higher mass resolution in the MALDI-TOF technique. The only necessary parameter for each specific TOF instrument is the geometric parameter η 0 = 2d/L, where d and L are the lengths of ion source and field-free drift tube.…”
Section: Discussionmentioning
confidence: 98%
“…Of course, from the standpoint of sensitivity and throughput, focusing is superior to filtering. However, one cannot achieve both spatial and energetic focusing through any combination of static fields (4). Therefore, the current practice is to achieve focus for one variable and minimize the effect of the other.…”
Section: Ion Focusing In Distance-of-flight and Time-of-flight Mass Smentioning
confidence: 99%
“…Efforts are still being made to improve the resolving power of the conventional commercial Wiley-McLaren instrument. Sanzone et al (41) have proposed an impulse field focussing technique whilst Enke's group (42) have considered various models for mass-independent space and energy focussing. Muga (43) has developed a commercial instrument based on a 'velocity compaction' technique in which a time-dependent acceleration voltage is used to compensate for the translational energy spread of ions ejected from a Wiley-McLaren ion source.…”
Section: Essentialmentioning