Our system is currently under heavy load due to increased usage. We're actively working on upgrades to improve performance. Thank you for your patience.
2015
DOI: 10.4236/wjet.2015.33c001
|View full text |Cite
|
Sign up to set email alerts
|

Modelling of the Radiological Contamination of the RBMK-1500 Reactor Control and Protection System Channels’ Cooling Circuit

Abstract: The article presents results of modelling and analysis of component contamination of the RBMK-1500 reactor Control and Protection System channels' Cooling Circuit (CPSCC) at Ignalina NPP Unit 1. The modelling was performed using a computer code LLWAA-DECOM (Tractebel Energy Engineering, Belgium), taking into consideration CPSCC components characteristics, parameters of the water flowing in the circuits, system work regimes, etc. During the modelling, results on activity of CPSCC components' deposits, nuclide c… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
3
0

Year Published

2019
2019
2019
2019

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(3 citation statements)
references
References 2 publications
0
3
0
Order By: Relevance
“…At the final shutdown of the reactor, radiation from the deposits on SP-HPR components is mostly determined by Mn-54, Co-58, Fe-59, and Co-60. But due to longer half-life, Co-60 is the most significant contributor to the total dose rate five years after [14], PCS [15], LSWS [16], and CPSCC [17] subsystems components compared to the MCC MCP activity (PCS-i:LSWS-i:CPSCC-i:SP-HPR-i / MCC pump).…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…At the final shutdown of the reactor, radiation from the deposits on SP-HPR components is mostly determined by Mn-54, Co-58, Fe-59, and Co-60. But due to longer half-life, Co-60 is the most significant contributor to the total dose rate five years after [14], PCS [15], LSWS [16], and CPSCC [17] subsystems components compared to the MCC MCP activity (PCS-i:LSWS-i:CPSCC-i:SP-HPR-i / MCC pump).…”
Section: Resultsmentioning
confidence: 99%
“…The scattering in the deposit activity ratio (at the final shutdown of the rector) between the most (the top of the bar) and the least (the bottom of the bar) contaminated components of the SP-HPR, MCC [14], PCS [15], LSWS [16], and CPSCC [17] systems compared to the activity of the MCC characteristic component (main circulation pump, MCP) is presented in Figure 5. As is shown in the chart, the activity of SP-HPR is lower than that of MCC and PCS nonpurified water subsystem.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation