2019
DOI: 10.1016/j.snb.2019.126770
|View full text |Cite
|
Sign up to set email alerts
|

Modelling of immunosensor response: the evaluation of binding kinetics between an immobilized receptor and structurally-different genetically engineered ligands

Abstract: In this research we have evaluated the binding kinetics between an immobilized receptor and several genetically engineered ligands, differing by molecular mass or by the number of binding sites available for the binding to the receptor. Genetically engineered protein (GCSF-Receptor), which contains some antibody parts (Fc domain) and at some extent is similar to antibody because also has two binding sites that selectively bind another proteinglycoprotein granulocyte colony stimulating factor (GCSF), which was … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
21
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
5
1

Relationship

3
3

Authors

Journals

citations
Cited by 19 publications
(21 citation statements)
references
References 27 publications
0
21
0
Order By: Relevance
“…The binding kinetics assay of the purified heterodimers and monomeric SCF to a surface-immobilized G-CSF and SCF receptors was performed by total internal reflection ellipsometry (TIRE). The binding assays of monomeric G-CSF and SCF-Lα-GCSF to GCSF-R were described in Balevicius et al (2019) . GCSF-R and c-kit used for TIRE are chimeric proteins (both obtained from Abcam).…”
Section: Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…The binding kinetics assay of the purified heterodimers and monomeric SCF to a surface-immobilized G-CSF and SCF receptors was performed by total internal reflection ellipsometry (TIRE). The binding assays of monomeric G-CSF and SCF-Lα-GCSF to GCSF-R were described in Balevicius et al (2019) . GCSF-R and c-kit used for TIRE are chimeric proteins (both obtained from Abcam).…”
Section: Methodsmentioning
confidence: 99%
“…The reaction chamber with a volume of 0.028 mL was positioned underneath the cell layer of the slide. Two gold sensor disks for immobilization of GCSF-R and c-kit were prepared as described previously ( Balevicius et al, 2014 , 2019 ) with slight modifications. Briefly, the BK7-glass/Cr-Au slides were cleaned using the BAL-TEC SCD 050 Sputter Coater plasma cleaner, washed with methanol for 10 min, and then rinsed with hexane for 5 min.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations