2020
DOI: 10.3103/s1068371220110103
|View full text |Cite
|
Sign up to set email alerts
|

Modeling Power-Supply Systems with Gas-Turbine Units as Energy Sources

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
2
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 1 publication
0
2
0
Order By: Relevance
“…where I i is a currents vector of element i, pI i is a currents derivative vector of element i, U i is the vector of voltages applied at the terminals of the element i, A i and B i are matrices whose dimension depends on the coordinate system in which the structural element is modeled, as well as on whether these equations are complete or simplified, and H i is the vector of impact on the element i [15]. The main models of elements in the transformed coordinates d and q of the PSS are shown (the generally accepted notations are used when writing systems of mathematical description):…”
Section: Mathematical Description Of the Power Supply Systemmentioning
confidence: 99%
See 2 more Smart Citations
“…where I i is a currents vector of element i, pI i is a currents derivative vector of element i, U i is the vector of voltages applied at the terminals of the element i, A i and B i are matrices whose dimension depends on the coordinate system in which the structural element is modeled, as well as on whether these equations are complete or simplified, and H i is the vector of impact on the element i [15]. The main models of elements in the transformed coordinates d and q of the PSS are shown (the generally accepted notations are used when writing systems of mathematical description):…”
Section: Mathematical Description Of the Power Supply Systemmentioning
confidence: 99%
“…In addition, the CTS-O with two power transformers of 1600 kVA is connected to the GTPS "Ilyichevskaya" (by cells 2 and 15), which includes the loads of the booster compressor modules (BCM) and the low-voltage loads of the GTPS units themselves. Furthermore, the GTPS "Ilyichevskaya" GPP provides the power supply to the oilfield and nearby settlement loads connected to the 10 kV busbar of the SS 35 kV "Ilyichevskaya" (Scheme 2) [15]. switchgear units 13, 14, and 16, accordingly.…”
Section: Model Of Oil and Gas Field Power Supply Systemmentioning
confidence: 99%
See 1 more Smart Citation
“…There are two ways in which distributed generation can be performed: it can work separately or in parallel with any existing centralized power supply system. The latter method for ensuring uninterruptible power supply is more widespread and can be called a hybrid power supply system or a grid-connected renewable energy system [3], [6]. In addition, in many countries, conventional centralized or public power supply systems are very old and unreliable but they cannot be replaced immediately by distributed generation [7].…”
Section: Introductionmentioning
confidence: 99%
“…Because of the success of hybrid-electric solution on conventional vehicles, piston engine is usually adopted in HPUs. In fact, turboshaft engine has higher power to weight ratio in comparison to piston engine, especially when it concerns high power requirement, and these advantages make the turboshaft engine have preferable performance in HPU [9]. ere are lots of obvious differences including but not limited to structure and aerospace features between the turboshaft engine and the piston engine, therefore the investigation on HPU with turboshaft engine is worth exploring for better performance of aerial vehicles [10].…”
Section: Introductionmentioning
confidence: 99%