2020
DOI: 10.1051/e3sconf/202017511017
|View full text |Cite
|
Sign up to set email alerts
|

Modeling of air handling processes in systems of conditioning premises

Abstract: Production premises should be provided with air conditioning in order to ensure and maintain required indoor climate parameters for proper technological process running. The paper presents analytical dependences that allow assessing the amount of heat supplied into a premise of processing meat products. A method of determining air parameters was proposed for implementing central conditioning under a technological process running in a premise. For a warm season, the air handling processes that involve or do not… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
3
1
1

Relationship

3
2

Authors

Journals

citations
Cited by 7 publications
(2 citation statements)
references
References 14 publications
0
1
0
Order By: Relevance
“…The method of passive experiment is based on the registration of the controlled parameters of the process in the mode of normal operation of the object without introducing any deliberate perturbations into it. The method of active experiment is based on the use of certain artificial perturbations introduced into the object according to a pre-planned program [5].…”
Section: Methodsmentioning
confidence: 99%
“…The method of passive experiment is based on the registration of the controlled parameters of the process in the mode of normal operation of the object without introducing any deliberate perturbations into it. The method of active experiment is based on the use of certain artificial perturbations introduced into the object according to a pre-planned program [5].…”
Section: Methodsmentioning
confidence: 99%
“…Determination of the parameters of the intermediate heat and cold carrier depending on the heat and technical efficiency of the air treatment process at tout=35 о С Thus, the dependence of the parameters of the heat exchange equipment and the operating modes of the transformed room is established. The regularities in the regulation of the system operation depending on the change in the load on the system are revealed.The cooling capacity of the installation is determined depending on the modes of use of the room at the outdoor temperature according to the formula[9][10][11]: air consumption, kg/h; o I the enthalpy of the outdoor air in the warm season, kJ/kg; c I -enthalpy of air leaving the air cooler, kJ/kg.The results of calculating the dependence of the ethylene glycol temperature at the inlet and outlet of the refrigerator on the cooling capacity refr Q are shown inFig. 7 and fig.…”
mentioning
confidence: 99%