“…The "Phasor" mode was used to solve the electrical circuit's transient states, allowing for a simulation lasting several tens of hours and an additional analysis of the results. Waqar et al and Babu simulated DGR implementation in an interconnected power network employing phasor measurement units (PMUs) to assign transients [15,16]. Plug-in electric vehicles as a prosumer (producer and consumer of electricity) require a special load frequency control technique on a network with low rotational inertia (with highly penetrated renewable energy sources (RESs)) [17][18][19][20][21].…”
Section: Related Workmentioning
confidence: 99%
See 1 more Smart Citation
“…The "Phasor" mode was used to solve the electrical circuit's transient states, allowing for a simulation lasting several tens of hours and an additional analysis of the results. Waqar et al and Babu simulated DGR implementation in an interconnected power network employing phasor measurement units (PMUs) to assign transients [15,16]. Plug-in electric vehicles as a prosumer (producer and consumer of electricity) require a special load frequency control technique on a network with low rotational inertia (with highly penetrated renewable energy sources (RESs)) [17][18][19][20][21].…”
Section: Related Workmentioning
confidence: 99%
“…∑ P PV_FARM + ∑ P GRID + ∑ P W I ND_FARM + ∑ P ESS + ∑ P DIESEL = ∑ P LOAD [W] (15) where ∑P TOTAL = ∑P G and ∑P LOAD = ∆P; ∑P PV_FARM is the total active power of the solar power plant (losses are included); ∑P WIND_FARM is the total active power of the wind power plant (losses are included); ∑P GRID is the total active power of DS; ∑P ESS is the total active power of the ESS, including BESS (losses are included); ∑P DIESEL is the total active power of the diesel generator; ∑P LOAD is the total active load power. The balance of reactive power at each time point also applies to the given simulation:…”
mentioning
confidence: 99%
“…In-fact, 55 millions of people were badly affected because of the shortage of electricity and it is considered as a ninth largest power outage in the world. Afterwards in February 2004, the US-Canada outage task force made a report about the incident which disturbed the power utilities and transmission lines [4]. Finally, they submitted a report to the government officials.…”
Section: Introductionmentioning
confidence: 99%
“…Besides, they recommended the use of PMU to get better visibility of power grids and avoid such incidents in future. Before there were few PMUs installed in the power network, after that incident (Blackout) number of PMUs are increased from 166 in 2010 to 1126 in 2014 [4]. Power system state estimation (PSSE) is conventionally a nonlinear problem, yet PMUs take the measurement and formulate it as a linear problem, it is easy to solve linear properties which are much simpler than nonlinear features [5].…”
Section: Introductionmentioning
confidence: 99%
“…15,886.0465 𝑉 = 1.58𝑘𝑉The transformer's output voltage supplied is 1.6*10 4 Vac, and this voltage is generated in cases where the simulation is phase-to-neutral. Subsequently, this is converted into a phase-tophase voltage, as shown.…”
mentioning
confidence: 99%