2009 17th IFIP International Conference on Very Large Scale Integration (VLSI-SoC) 2009
DOI: 10.1109/vlsisoc.2009.6041327
|View full text |Cite
|
Sign up to set email alerts
|

Modeling and dynamic management of 3D multicore systems with liquid cooling

Abstract: Abstract-Three-dimensional (3D) circuits reduce communication delay in multicore SoCs, and enable efficient integration of cores, memories, sensors, and RF devices. However, vertical integration of layers exacerbates the reliability and thermal problems, and cooling efficiency becomes a limiting factor. Liquid cooling is a solution to overcome the accelerated thermal problems imposed by multi-layer architectures. In this paper, we first provide a 3D thermal simulation model including liquid cooling, supporting… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
57
0

Year Published

2010
2010
2021
2021

Publication Types

Select...
5
2
1

Relationship

3
5

Authors

Journals

citations
Cited by 58 publications
(57 citation statements)
references
References 29 publications
0
57
0
Order By: Relevance
“…Removing the heat using fan from a heat sink attached to a package (integrated circuit) and Dynamic Frequency Voltage Scaling (DFVS) are considered as a conventional thermal management [1,3]. The temperature of an element (chip, heat sink, etc.)…”
Section: Introductionmentioning
confidence: 99%
“…Removing the heat using fan from a heat sink attached to a package (integrated circuit) and Dynamic Frequency Voltage Scaling (DFVS) are considered as a conventional thermal management [1,3]. The temperature of an element (chip, heat sink, etc.)…”
Section: Introductionmentioning
confidence: 99%
“…Another class of applications which require runtime thermal simulation is fine grain control: where thermal data is required at a finer granularity than can be provided by thermal sensors. Examples include register assignment optimization [3] and liquid coolant flow control in 3d chips [4].…”
Section: Introductionmentioning
confidence: 99%
“…3) Thermal Management of Liquid-Cooled 3D MPSoCs Prior liquid cooling work [90] evaluates existing thermal management policies on a 3D MPSoC with a fixedflow rate setting, and also investigates the benefits of variable flow using a policy to increment or decrement the flow rate based on temperature measurements, but without considering pump energy consumption.…”
Section: ) Power and Thermal Management Of Air-cooled 2d And 3d Mpsocsmentioning
confidence: 99%