2011 IEEE Power and Energy Society General Meeting 2011
DOI: 10.1109/pes.2011.6038947
|View full text |Cite
|
Sign up to set email alerts
|

Model validation for wind turbine generator models

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
50
0
1

Year Published

2012
2012
2022
2022

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 39 publications
(51 citation statements)
references
References 0 publications
0
50
0
1
Order By: Relevance
“…This model is based on the idea that from the Point of Common Coupling (PCC), the machine performance is not relevant, because it is decoupled from the grid by a power converter [7]. Therefore, the drive train model, synchronous machine and machine-side converter can be omitted.…”
Section: First Reduced Order Model: DC Current Source Modelmentioning
confidence: 99%
See 2 more Smart Citations
“…This model is based on the idea that from the Point of Common Coupling (PCC), the machine performance is not relevant, because it is decoupled from the grid by a power converter [7]. Therefore, the drive train model, synchronous machine and machine-side converter can be omitted.…”
Section: First Reduced Order Model: DC Current Source Modelmentioning
confidence: 99%
“…These models have been applied for transient stability studies in wind speed variations [3][4][5][6], voltage ride-through capability [1,3,5,7,8], reactive power compensation [7], frequency support capability [9][10][11] and for steady-state studies in harmonic propagation [12,13] and load flow analysis [14].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…However, this situation will improve in the future, as working groups of different organizations are developing standard dynamic models for new generation equipment, such as the Western Electricity Coordinating Council [20], IEEE [21] or IEC [22].…”
Section: A General Remarksmentioning
confidence: 99%
“…In order to reduce the negative effects of grid connection, the grid code of all countries has introduced more and more strictly requirements, such as high accuracy of wind farm power forecasting 907 system, multiple ways of active power regulation, fast and efficient reactive power regulation like voltage control, power factor regulation and reactive power regulation [3][4][5]. Meanwhile, high accuracy and complex wind farm and wind turbine model has provided a strong basis for grid planning, dispatching, operation, scientific research and other fields [6][7][8]. This paper will introduce a kind of method to realize advanced wind farm reactive power control system, which contains a wind farm calculator, transformer and feeder compensation, and wind turbine var distribution system, and then it implement the advanced control system into the modeling platform using DIgSILENT and Matlab to realize the function and performance; at last, we use the optimized advanced control system in a wind farm which contains 33 sets of 1.5MW wind turbines to compare the control result with simulation, where the parameter of facilities and control system is almost the same.…”
Section: Introductionmentioning
confidence: 99%