2014
DOI: 10.3390/en7117694
|View full text |Cite
|
Sign up to set email alerts
|

High Performance Reduced Order Models for Wind Turbines with Full-Scale Converters Applied on Grid Interconnection Studies

Abstract: Wind power has achieved technological evolution, and Grid Code (GC) requirements forced wind industry consolidation in the last three decades. However, more studies are necessary to understand how the dynamics inherent in this energy source interact with the power system. Traditional energy production usually contains few high power unit generators; however, Wind Power Plants (WPPs) consist of dozens or hundreds of low-power units. Time domain simulations of WPPs may take too much time if detailed models are c… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
9
0
4

Year Published

2015
2015
2021
2021

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 21 publications
(13 citation statements)
references
References 33 publications
0
9
0
4
Order By: Relevance
“…The active power injected into the grid at the PCC for a particular PV system depends upon I dref , which is calculated using the PQ theory [33]. For detailed modelling, see [34].…”
Section: Pv Systemmentioning
confidence: 99%
See 1 more Smart Citation
“…The active power injected into the grid at the PCC for a particular PV system depends upon I dref , which is calculated using the PQ theory [33]. For detailed modelling, see [34].…”
Section: Pv Systemmentioning
confidence: 99%
“…To quantify the voltage magnitude and unbalance at all buses, a performance index (PI) is defined in Equation 5. Several disparate PIs are proposed in the literature [34][35][36]. Because the assessment of voltage quality highly depends on PI definition, it is crucial to delineate PI.…”
Section: Performance Index and Proposed Techniquesmentioning
confidence: 99%
“…No controle vetorial clássico, somente as componentes dq 1 da corrente do rotor são controladas e portanto só é possível o controle de duas das componentes de potência de (30), em geral as potências ativa e reativa médias ( 0 e 0 ). Porém, ao se controlarem também as componentes dq 2 da corrente do rotor, dois outros parâmetros podem ser controlados, sendo que em [9] são tratados dos seguintes objetivos: I. Corrente de rotor equilibrada ( 2 = 2 = 0).…”
Section: B Determinação Das Referências De Correnteunclassified
“…Para se confirmar que as referências de corrente foram devidamente determinadas e que o controle está atuando de forma adequada, é necessário o cálculo das componentes das potências ativa e reativa do estator. Para tal, de (30), as tensões da rede elétrica e correntes do estator devem estar representadas nos referenciais dq 1 e dq 2 .…”
Section: Obtenção Das Componentes Em Dq 1 E Dqunclassified
“…Além destas, a Figura 9 também traz a resposta simulada da planta com ′ = 0,5712 Ω (a planta com os valores de ′ e ′ da Tabela II), de forma a mostrar como esta difere das respostas obtidas a partir do método de estimação de parâmetros proposto. Para avaliar de forma quantitativa a aproximação das curvas simuladas em relação às obtidas experimentalmente, será utilizado o índice de desempenho proposto em [26], chamado de integral normalizada do erro absoluto (NIAE, do inglês Normalized Integral of Absolute Error), sendo:…”
Section: Fig 9 Variação Dos Polos Da Plantaunclassified