2002
DOI: 10.1053/jhin.2001.1164
|View full text |Cite
|
Sign up to set email alerts
|

Mobile zoned/exponential LAF screen: a new concept in ultra-clean air technology for additional operating room ventilation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
26
0

Year Published

2005
2005
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 34 publications
(27 citation statements)
references
References 20 publications
(15 reference statements)
1
26
0
Order By: Relevance
“…As expected, the maximum impact was recorded in the centre of the air flow with RFs of >50 (>98% reduction) in both types of ventilation. The present results were in accordance with those obtained by Friberg et al 4 using the TOUL-400 unit at a distance of 1.0e1.2 m from the screen. Interestingly, in both types of impact area mapping experiments (Figure 2a and b), the present study found a dramatic localized impact of the TOUL-400 unit on the deposition rate (recorded on a single 14-cm plate) and apparently representing the focus of the clean-air stream (e.g.…”
Section: Discussionsupporting
confidence: 94%
See 2 more Smart Citations
“…As expected, the maximum impact was recorded in the centre of the air flow with RFs of >50 (>98% reduction) in both types of ventilation. The present results were in accordance with those obtained by Friberg et al 4 using the TOUL-400 unit at a distance of 1.0e1.2 m from the screen. Interestingly, in both types of impact area mapping experiments (Figure 2a and b), the present study found a dramatic localized impact of the TOUL-400 unit on the deposition rate (recorded on a single 14-cm plate) and apparently representing the focus of the clean-air stream (e.g.…”
Section: Discussionsupporting
confidence: 94%
“…In contrast, Friberg et al 4 obtained RFs of 22e70 with the TOUL-400 unit during sham hip operations performed in an OR but at a distance of only 0.75e1.0 m, again emphasizing the limited reach of the TOUL-400 unit.…”
Section: Discussionmentioning
confidence: 94%
See 1 more Smart Citation
“…One method to measure the performance is either to use Petri dishes to sample deposition of bacteria during an operation, or to use a bacterial air sampler to measure the concentration of airborne bacteria [7][8][9]. This is a very direct way to evaluate risk, but because factors such as quality of clothing and procedures influence the result, this method is unsuited for comparison between systems in different hospitals.…”
Section: Introductionmentioning
confidence: 99%
“…For example, in a pilot experiment, a mobile ultraclean laminar air unit provided the equivalent air quality of a UCV theatre. 11 The future role of technology in evolving surgical practice in terms of minimizing infection is unclear.…”
Section: Introductionmentioning
confidence: 99%