2018
DOI: 10.1016/j.bpc.2018.04.005
|View full text |Cite
|
Sign up to set email alerts
|

Mixing behaviour of asymmetrical glycerol diether bolalipids with saturated and unsaturated phosphatidylcholines

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 55 publications
0
3
0
Order By: Relevance
“…During this project, two novel classes of artificial bolalipids, the glycerol diether bolalipids [160,161] and alkyl-substituted single-chain bolalipids [162,163], were synthesized and characterized. Drescher and his group could show that these artificial bolalipids are miscible with unsaturated phospholipids [164,165], and that these mixed vesicles (bolasomes) show promising results regarding the stability of those bolasomes in artificial digestive media [166]. However, these bolalipid-doped liposomes require further investigation before they can be used as a drug delivery system.…”
Section: Principalmentioning
confidence: 99%
“…During this project, two novel classes of artificial bolalipids, the glycerol diether bolalipids [160,161] and alkyl-substituted single-chain bolalipids [162,163], were synthesized and characterized. Drescher and his group could show that these artificial bolalipids are miscible with unsaturated phospholipids [164,165], and that these mixed vesicles (bolasomes) show promising results regarding the stability of those bolasomes in artificial digestive media [166]. However, these bolalipid-doped liposomes require further investigation before they can be used as a drug delivery system.…”
Section: Principalmentioning
confidence: 99%
“…As published previously [53,56], DSC measurements were carried out using a MicroCal VP-DSC differential scanning calorimeter (MicroCal Inc. Northampton, MA, USA). Before each measurement, the lipid dispersion (c = 3 mM) and the reference were degassed under vacuum while stirring.…”
Section: Differential Scanning Calorimetry (Dsc)mentioning
confidence: 99%
“…In accordance to a procedure described previously [56], vitrified specimens for cryo-TEM were prepared by a blotting procedure using an EM GP grid plunger (Leica, Wetzlar, Germany), and an atmospheric chamber with controlled humidity (80%) and temperature (T = 22 • C). For cryo-fixation, a drop of the sample solution (c = 3 mM) was placed onto an EM grid that is coated with a holey carbon film (C-flat, Protochip Inc., Raleight, NC, USA).…”
Section: Transmission Electron Microscopy Of Vitrified Specimens (Crymentioning
confidence: 99%