Mitral valve size measurement in North Karnataka by using cardiac sizer: A cadaveric study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

2
1
1

Year Published

2016
2016
2022
2022

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 13 publications
2
1
1
Order By: Relevance
“…In the present study a circumference between 7.5 -8.5 cm was found in maximum number of specimens (40%) which was similar with the values reported by many other observers. 13,19,20,25 The mean diameter of mitral valve in present study was 2.01 ± 0.27cm (Table 4) which was similar with the studies by Gunnal 14 but lower than the values of other researcher where they had used a cardiac sizer for measurement. 19 The present mean value was also lower than the values of other observers.…”
Section: Dimensions Of Mitral Valvesupporting
confidence: 84%
See 1 more Smart Citation
“…In the present study a circumference between 7.5 -8.5 cm was found in maximum number of specimens (40%) which was similar with the values reported by many other observers. 13,19,20,25 The mean diameter of mitral valve in present study was 2.01 ± 0.27cm (Table 4) which was similar with the studies by Gunnal 14 but lower than the values of other researcher where they had used a cardiac sizer for measurement. 19 The present mean value was also lower than the values of other observers.…”
Section: Dimensions Of Mitral Valvesupporting
confidence: 84%
“…13,19,20,25 The mean diameter of mitral valve in present study was 2.01 ± 0.27cm (Table 4) which was similar with the studies by Gunnal 14 but lower than the values of other researcher where they had used a cardiac sizer for measurement. 19 The present mean value was also lower than the values of other observers. 21,26 Though there was no direct relation between the diameter and the annular circumference of the same valve, generally with larger circumference the diameter was found to be longer.…”
Section: Dimensions Of Mitral Valvesupporting
confidence: 84%
“…The majority (72%) of the mitral valves had a circumference ranging from 7.53 to 8.47 cm in his study. [24] These values are lesser than our study. This difference may be due to the difference in method and material between our study and their study.…”
contrasting
confidence: 79%
“…Dissection method Guptha et al [21] 9.11 ± 0.44 cm in both 18 Dissection method S A Cheema [22] 10.7 in males 9.16 in females -Dissection method Omriston et al [23] 9.3±0.9 in both 11 2D Echo Amgain et al [24] 8.03±0.8 in both 50…”
mentioning
confidence: 99%