2020
DOI: 10.1007/s12010-020-03285-y
|View full text |Cite
|
Sign up to set email alerts
|

MIP-Based Impedimetric Sensor for Detecting Dengue Fever Biomarker

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
32
1

Year Published

2020
2020
2023
2023

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 66 publications
(35 citation statements)
references
References 31 publications
0
32
1
Order By: Relevance
“…They showed that the impedimetric measurements had a linear response curve in the concentration range (1‐200 ng/ml) and the electrochemical medical biosensor can specifically detect non‐structural protein 1 as low as 0.3 ng/ml. They also performed experiments in human serum and obtained satisfying recovery values from 95 to 97.14% with less than 5% of standard deviations (Arshad et al, 2020). Dolai and Tabib ‐ Azar reported a paper‐based potentiometric medical biosensor to identify the Zika virus with a minimum sensitivity (0.26 nV/Zika) and a detectable signal (2.4 × 10 7 Zika).…”
Section: Recent Studies Of Medical Biosensorsmentioning
confidence: 97%
“…They showed that the impedimetric measurements had a linear response curve in the concentration range (1‐200 ng/ml) and the electrochemical medical biosensor can specifically detect non‐structural protein 1 as low as 0.3 ng/ml. They also performed experiments in human serum and obtained satisfying recovery values from 95 to 97.14% with less than 5% of standard deviations (Arshad et al, 2020). Dolai and Tabib ‐ Azar reported a paper‐based potentiometric medical biosensor to identify the Zika virus with a minimum sensitivity (0.26 nV/Zika) and a detectable signal (2.4 × 10 7 Zika).…”
Section: Recent Studies Of Medical Biosensorsmentioning
confidence: 97%
“…In the immune system, antibodies must be specific in recognizing certain antigens. MIP as an alternative to antibodies is often used as an analytical method for diagnostic purposes [ 40 ], such as breast cancer diagnostics [ 41 ], cardiovascular disease [ 42 ], and dengue fever [ 43 ]. Therefore, MIP acts as a biomarker [ 44 ] because it is able to show certain physical characteristics or measurable biologically generated changes in the body associated with certain diseases or health conditions [ 45 ].…”
Section: Mip Applicationmentioning
confidence: 99%
“…Moreover, EIS offers label free detection of specific antigen-antibody reactions [145]. Till now, different electrochemical based biosensor development approaches have been reported, including carbon nanotube, screen printing, gold nanoparticles, and peptides [148][149][150][151]. EIS technology based on gold nanoparticles (AuNPs) was developed for DENV 1-4 [145].…”
Section: Electrochemical Sensing-based Technologiesmentioning
confidence: 99%