2022
DOI: 10.1088/1748-0221/17/03/c03019
|View full text |Cite
|
Sign up to set email alerts
|

MiniPIX Timepix3 — a miniaturized radiation camera with onboard data processing for online characterization of wide-intensity mixed-radiation fields

Abstract: The miniaturized radiation camera MiniPIX TPX3 is designed for detailed and wide-range measurements of mixed-radiation fields present in many applications such as radiotherapy and space radiation in outer orbit. The highly integrated instrumentation utilizes a single connector for control and readout for flexible measurements and quick deployment. The device features an option to process the registered data on the same device with limited resolution and basic particle-type resolving power. A novel readout and … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
14
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 10 publications
(14 citation statements)
references
References 9 publications
(21 reference statements)
0
14
0
Order By: Relevance
“…We use a Timepix3 detector [12] with integrated readout electronics as a miniaturized radiation camera MiniPIX-TPX3 [27] from Advacam as shown in figure 1. The Timepix3 ASIC chip was equipped with a 500 μm silicon sensor.…”
Section: Radiation Camera Minipix Tpx3 With Neutron Converter Maskmentioning
confidence: 99%
“…We use a Timepix3 detector [12] with integrated readout electronics as a miniaturized radiation camera MiniPIX-TPX3 [27] from Advacam as shown in figure 1. The Timepix3 ASIC chip was equipped with a 500 μm silicon sensor.…”
Section: Radiation Camera Minipix Tpx3 With Neutron Converter Maskmentioning
confidence: 99%
“…We examine and analyze the scattered particles in detail with spectral-sensitive tracking response in wide field-of-view (FoV). This is made possible by use of the pixel detector Timepix3 [5] assembled as a compact radiation camera [6] which can be easily placed in arbitrary proximity to the foil and safely away from the primary beam axis.…”
Section: Motivation Aimsmentioning
confidence: 99%
“…We use the miniaturized radiation camera MiniPIX-Timepix3 [6] equipped with the Timepix3 ASIC chip [5] bump-bonded to a 500 μm thick silicon sensor (figure 1a). The camera operates at room temperature with integrated power, control and data readout enabled via single USB 2.0 connector to standard PC.…”
Section: Miniaturized Radiation Camera Minipix-timepix3mentioning
confidence: 99%
“…For the experimental verification a 7×7 pixel matrix of Minipix Timepix3 [7] was irradiated with photons of an Am-241 source. The configuration of the simulation which was utilized to generate the probability maps matched the one used in the measurement (bias = 200 V for 500 μm Silicon sensor, DAC value for Ikrum = 5).…”
Section: Experimental Verification 241 Application Of Correction Maps...mentioning
confidence: 99%