The semiconductor pixel detector Timepix contains an array of 256 × 256 square pixels with pitch 55 µm. In addition to high spatial granularity the single quantum counting detector Timepix can provide also energy or time information in each pixel. This device is a powerful tool for radiation and particle detection, imaging and tracking. A new readout interface for silicon pixel detectors of the Medipix family has been developed in our group in order to provide a higher frame rate and enhanced flexibility of operation. The interface consists of a field programmable gate array, a USB 2.0 interface chip, DAC, ADC and a circuit which generates bias voltage for the sensor. The main control system is placed in the FPGA circuit which fully controls the Timepix device. This approach offers an easy way how to include new functionality and extended operation. The interface for Timepix supports all operation modes of the detector (counting, TOT, timing). The FITPix is a successor of the USB 1.22 Interface and the electronic readout is built with the latest available components, which allows achieving up to 90 frames per second with a single detector. The frame rate is about 20 times faster compared to the previous system while it maintains all same capabilities supported. In addition FITPix newly enables an adjustable clock frequency and hardware triggering which is a useful tool when there is the need for synchronized operation of multiple devices. Three modes of hardware trigger have been implemented: hardware trigger which starts the measurement, hardware trigger which terminates the measurement and hardware trigger which controls measurement fully. The entire system is fully powered through the USB bus. FITPix supports also readout from several detectors in chain in which case just an external power source is required. FITPix is a fully flexible device and the user needs no other equipment. FITPix combines high performance and mobility and it opens new fields of applications. The current version of the FITPix interface has dimension 45 mm × 60 mm.
Radiotherapy with narrow scanned carbon ion beams enables a highly accurate treatment of tumours while sparing the surrounding healthy tissue. Changes in the patient's geometry can alter the actual ion range in tissue and result in unfavourable changes in the dose distribution. Consequently, it is desired to verify the actual beam delivery within the patient. Real-time and non-invasive measurement methods are preferable. Currently, the only technically feasible method to monitor the delivered dose distribution within the patient is based on tissue activation measurements by means of positron emission tomography (PET). An alternative monitoring method based on tracking of prompt secondary ions leaving a patient irradiated with carbon ion beams has been previously suggested. It is expected to help in overcoming the limitations of the PET-based technique like physiological washout of the beam induced activity, low signal and to allow for real-time measurements. In this paper, measurements of secondary charged particle tracks around a head-sized homogeneous PMMA phantom irradiated with pencil-like carbon ion beams are presented. The investigated energies and beam widths are within the therapeutically used range. The aim of the study is to deduce properties of the primary beam from the distribution of the secondary charged particles. Experiments were performed at the Heidelberg Ion Beam Therapy Center, Germany. The directions of secondary charged particles emerging from the PMMA phantom were measured using an arrangement of two parallel pixelated silicon detectors (Timepix). The distribution of the registered particle tracks was analysed to deduce its dependence on clinically important beam parameters: beam range, width and position. Distinct dependencies of the secondary particle tracks on the properties of the primary carbon ion beam were observed. In the particular experimental set-up used, beam range differences of 1.3 mm were detectable. In addition, variations in the beam width could be measured with a precision of 0.9 mm. Furthermore, shifts of the lateral beam position could be monitored with a sub-millimetre precision. The presented investigations demonstrate experimentally that the non-invasive measurement and analysis of secondary ion distributions around head-sized homogeneous objects provide information on the actual beam delivery. Beam range, width and position could be monitored with a precision attractive for therapeutic situations.
The hybrid particle counting pixel detectors of Medipix family are well known. In this contribution we present new USB 3.0 based interface AdvaDAQ for Timepix3 detector. The AdvaDAQ interface is designed with a maximal emphasis to the flexibility. It is successor of FitPIX interface developed in IEAP CTU in Prague. Its modular architecture supports all Medipix/Timepix chips and all their different readout modes: Medipix2, Timepix (serial and parallel), Medipix3 and Timepix3. The high bandwidth of USB 3.0 permits readout of 1700 full frames per second with Timepix or 8 channel data acquisition from Timepix3 at frequency of 320 MHz. The control and data acquisition is integrated in a multiplatform PiXet software (MS Windows, Mac OS, Linux). In the second part of the publication a new method for correction of the time-walk effect in Timepix3 is described. Moreover, a fully spectroscopic X-ray imaging with Timepix3 detector operated in the ToT mode (Time-over-Threshold) is presented. It is shown that the AdvaDAQ's readout speed is sufficient to perform spectroscopic measurement at full intensity of radiographic setups equipped with nano-or micro-focus X-ray tubes.
The superior properties of the single particle counting semiconductor pixel detectors in radiation imaging are well known. They are namely: very high dynamic range due to digital counting, absence of integration and read-out noise, high spatial resolution and energy sensitivity. The major disadvantage of current pixel devices preventing their broad exploitation has been their relatively small sensitive area of few cm2. This disadvantage is often solved using tiling method placing many detector units side by side forming a large matrix. The current tiling techniques require rather large gaps of few millimeters between tiles. These gaps stand as areas insensitive to radiation which is acceptable only in some applications such as diffraction imaging. However standard transmission radiography requires fully continuous area sensitivity. In this article we present the new large area device WIDEPIX composed of a matrix of 10 × 10 tiles of silicon pixel detectors Timepix (each of 256 × 256 pixels with pitch of 55 μm) having fully sensitive area of 14.3 × 14.3 cm2 without any gaps between the tiles. The device contains a total of 6.5 mega pixels. This achievement was reached thanks to new technology of edgeless semiconductor sensors together with precise alignment technique and multilevel architecture of readout electronics. The mechanical construction of the device is fully modular and scalable. This concept allows replacing any single detector tile which significantly improves production yield. The first results in the field of X-ray radiography and material sensitive X-ray radiography are presented in this article.
Position sensitive detectors are evolving towards higher segmentation geometries from 0D (single pad) over 1D (strip) to 2D (pixel) detectors. Each step has brought up substantial expansion in the field of applications. The next logical step in this evolution is to design a 3D, i.e. voxel detector.The voxel detector can be constructed from 2D volume element detectors arranged in layers forming a 3D matrix of sensitive elements -voxels. Such detectors can effectively record tracks of energetic particles. By proper analysis of these tracks it is possible to determine the type, direction and energy of the primary particle. One of the prominent applications of such device is in the localization and identification of gamma and neutron sources in the environment. It can be also used for emission and transmission radiography in many fields where standard imagers are currently utilized. The qualitative properties of current imagers such as: spatial resolution, efficiency, directional sensitivity, energy sensitivity and selectivity (background suppression) can be improved.The first prototype of a voxel detector was built using a number of Timepix devices. Timepix is hybrid semiconductor detector consisting of a segmented semiconductor sensor bump-bonded to a readout chip. Each sensor contains 256x256 square pixels of 55 µm size.The voxel detector prototype was successfully tested to prove the concept functionality. The detector has a modular architecture with a daisy chain connection of the individual detector layers. This permits easy rearrangement due to its modularity, while keeping a single readout system for a variable number of detector layers. A limitation of this approach is the relatively large inter-layer distance (4 mm) compared to the pixel thickness (0.3 mm). Therefore the next step in the design is to decrease the space between the 2D detectors.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.