2021
DOI: 10.1088/1361-6560/abffbb
|View full text |Cite
|
Sign up to set email alerts
|

Miniaturized scintillator dosimeter for small field radiation therapy

Abstract: The concept of a miniaturized inorganic scintillator detector is demonstrated in the analysis of the small static photon fields used in external radiation therapy. Such a detector is constituted by a 0.25 mm diameter and 0.48 mm long inorganic scintillating cell (1.6 × 10−5 cm3 detection volume) efficiently coupled to a narrow 125 μm diameter silica optical fiber using a tiny photonic interface (an optical antenna). The response of our miniaturized scintillator detector (MSD) under 6 MV bremsstrahlung beam of … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
12
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 11 publications
(12 citation statements)
references
References 44 publications
0
12
0
Order By: Relevance
“…As an alternative approach, the concept of a miniaturized scintillator detector (MSD) has been recently introduced from the harnessing of inorganic scintillators to a narrow 125-µm diameter silica fiber with a microfabricated photonic antenna (Suarez et al 2019). A MSD with a detection volume as small as 0.016 mm 3 (0.25-mm diameter and 0.48-mm long ellipsoid) has been demonstrated in external beam radiotherapy (Gonod et al 2021). The MSD has been shown to overcome the stem effect, and despite its water nonequivalence (both scintillator and fiber), it minimizes electron fluence perturbation due to its extreme compactness.…”
Section: Introductionmentioning
confidence: 99%
“…As an alternative approach, the concept of a miniaturized scintillator detector (MSD) has been recently introduced from the harnessing of inorganic scintillators to a narrow 125-µm diameter silica fiber with a microfabricated photonic antenna (Suarez et al 2019). A MSD with a detection volume as small as 0.016 mm 3 (0.25-mm diameter and 0.48-mm long ellipsoid) has been demonstrated in external beam radiotherapy (Gonod et al 2021). The MSD has been shown to overcome the stem effect, and despite its water nonequivalence (both scintillator and fiber), it minimizes electron fluence perturbation due to its extreme compactness.…”
Section: Introductionmentioning
confidence: 99%
“…The overall fabrication process is detailed in Refs. [29, 30]. The MPD is locally enlarged to diameters around 320 microns by the presence of the scintillating cells (see Figure 1c).…”
Section: Methodsmentioning
confidence: 99%
“…Using such small field sizes, accurate and reliable dose measurements methods are required. 7 , 8 , 9 , 10 , 11 , 12 , 13 …”
Section: Introductionmentioning
confidence: 99%
“…The iris collimator creates fields of polygon with different sizes from 5 mm to 60 mm. Using such small field sizes, accurate and reliable dose measurements methods are required 7–13 …”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation