ObjectSince the 1990s, Gamma Knife radiosurgery (GKRS) has become the first-line treatment option for small- to medium-size vestibular schwannomas (VSs), especially in patients without mass effect–related symptoms and with functional hearing. The aim of this study was to assess the safety and efficacy of GKRS, in terms of tumor control, hearing preservation, and complications, in a series of 379 consecutive patients treated for VS.MethodsOf 523 patients treated at the authors' institution for VS between 2001 and 2010, the authors included 379 who underwent GKRS as the primary treatment. These patients were not affected by Type 2 neurofibromatosis and had clinical follow-up of at least 36 months. Clinical follow-up (mean and median 75.7 and 69.5 months, respectively) was performed for all patients, whereas audiometric and quantitative radiological follow-up examinations were obtained for only 153 and 219 patients, respectively. The patients' ages ranged from 23 to 85 years (mean 59 years). The mean tumor volume was 1.94 ± 2.2 cm3 (median 1.2 cm3, range 0.013–14.3 cm3), and the median margin dose was 13 Gy (range 11–15 Gy). Parameters considered as determinants of the clinical outcome were long-term tumor control, hearing preservation, and complications. A statistical analysis was performed to correlate clinical outcomes with the radiological features of the tumor, dose-planning parameters, and patient characteristics.ResultsControl of the tumor with GKRS was achieved in 97.1% of the patients. In 82.7% of the patients, the tumor volume had decreased at the last follow-up, with a mean relative reduction of 34.1%. The rate of complications was very low, with most consisting of a transient worsening of preexisting symptoms. Patients who had vertigo, balance disorders, or facial or trigeminal impairment usually experienced a complete or at least significant symptom relief after treatment. However, no significant improvement was observed in patients previously reporting tinnitus. The overall rate of preservation of functional hearing at the long-term follow-up was 49%; in patients with hearing classified as Gardner-Robertson (GR) Class I, this value was 71% and reached 93% among cases of GR Class I hearing in patients younger than 55 years.ConclusionsGamma Knife radiosurgery is a safe and effective treatment for VS, achieving tumor control in 97.1% of cases and resulting in a very low morbidity rate. Younger GR Class I patients had a significantly higher probability of retaining functional hearing even at the 10-year follow-up; for this reason, the time between symptom onset, diagnosis, and treatment should be shortened to achieve better outcomes in functional hearing preservation.
In stereotactic radiosurgery the choice of appropriate detectors, whether for absolute or relative dosimetry, is very important due to the steep dose gradient and the incomplete lateral electronic equilibrium. For both linac-based and Leksell Gamma Knife radiosurgery units, we tested the use of calibrated radiochromic film to measure absolute doses and relative dose distributions. In addition a small diode was used to estimate the relative output factors. The data obtained using radiochromic and diode detectors were compared with measurements performed with other conventional methods of dosimetry, with calculated values by treatment planning systems and with data prestored in the treatment planning system supplied by the Leksell Gamma Knife (LGK) vendor. Two stereotactic radiosurgery techniques were considered: Leksell Gamma Knife (using gamma-rays from 60Co) and linac-based radiosurgery (LR) (6 MV x-rays). Different detectors were used for both relative and absolute dosimetry: relative output factors (OFs) were estimated by using radiochromic and radiographic films and a small diode; relative dose distributions in the axial and coronal planes of a spherical polystyrene phantom were measured using radiochromic film and calculated by two different treatment planning systems (TPSs). The absolute dose at the sphere centre was measured by radiochromic film and a small ionization chamber. An accurate selection of radiochromic film was made: samples of unexposed film showing a percentage standard deviation of less than 3% were used for relative dose profiles, and for absolute dose and OF evaluations this value was reduced to 1.5%. Moreover a proper calibration curve was made for each set of measurements. With regard to absolute doses, the results obtained with the ionization chamber are in good correlation with radiochromic film-generated data, for both LGK and LR, showing a dose difference of less than 1%. The output factor evaluations, performed using different methods, are in good agreement with a maximum difference of 1.5% for all field sizes considered (LGK and LR) except the 4 mm helmet used in the LGK unit. In this case, differences exist between diode and radiochromic film measurements and both detectors show data values larger than the prestored OF value of 0.80. Dose profiles measured by radiochromic film and calculated are in excellent agreement for both LGK and LR with a maximum deviation of less than 1.0 mm, when full widths of the dose profiles at 20%, 50%, 80% levels are considered. When external photon beams are used in stereotactic radiosurgery, the 'well selected' radiochromic films are very accurate detectors both for relative and absolute dosimetry. The experimental results, obtained using both radiochromic and diode detectors, show that the 4 mm helmet relative output factor could be underestimated.
PurposeThe main purpose of this work was to compare peripheral doses absorbed during stereotactic treatment of a brain lesion delivered using different devices. These data were used to estimate the risk of stochastic effects.MethodsTreatment plans were created for an anthropomorphic phantom and delivered using a LINAC with stereotactic cones and a multileaf collimator, a CyberKnife® system (before and after a supplemental shielding was applied), a TomoTherapy® system, and a Gamma Knife® unit. For each treatment, 5 Gy were prescribed to the target. Measurements were performed with thermoluminescent dosimeters inserted roughly in the position of the thyroid, sternum, upper lung, lower lung, and gonads.ResultsMean doses ranged from of 4.1 (Gamma Knife) to 62.8 mGy (LINAC with cones) in the thyroid, from 2.3 (TomoTherapy) to 30 mGy (preshielding CyberKnife) in the sternum, from 1.7 (TomoTherapy) to 20 mGy (preshielding CyberKnife) in the upper part of the lungs, from 0.98 (Gamma Knife) to 15 mGy (preshielding CyberKnife) in the lower part of the lungs, and between 0.3 (Gamma Knife) and 10 mGy (preshielding CyberKnife) in the gonads.ConclusionsThe peripheral dose absorbed in the sites of interest with a 5 Gy fraction is low. Although the risk of adverse side effects calculated for 20 Gy delivered in 5 Gy fractions is negligible, in the interest of optimum patient radioprotection, further studies are needed to determine the weight of each contributor to the peripheral dose.
We found clinical and dosimetric variables to clearly predict the risk of the main side effects after GKRS for UM. These results may provide dose constraints to critical structures, potentially able to reduce side effects. Constraining D1% to the optic nerve below 12-13Gy may result in a dramatic reduction of blindness risk, while reducing V20 of the posterior segment of the bulb could limit the neovascular glaucoma onset.
GKRS was effective for controlling the growth of residual or recurrent craniopharyngioma. Serious side effects were uncommon. Multisession GKRS seems a very promising tool to allow performing GKRS even in patients with large residual or recurrent craniopharyngioma.
The purpose of this study was to evaluate radiation doses to the patients and operators during interventional cardiology procedures, with a particular focus on the transcatheter aortic valve implantation (TAVI). Patient doses for 5549 diagnostic and therapeutic procedures and 76 TAVI were examined, as well as occupational doses to Cardiology Department operators. The average patient dose for TAVI was double that of PTCA and six times higher than a simple CA; statistically significant differences were shown in the average patient dose for both transfemoral and transapical access; the measurements show a corresponding increase in the average occupational dose for the cardiologist. Interventional cardiology could increase the collective dose and occupationally exposed worker doses; this increase could be significant if the use of certain procedures is extended to younger people; particular attention in the choice of procedure, optimisation and staff education and organisation is therefore suggested.
an advanced MHz-class repetition rate X-ray source for linear regime time-resolved spectroscopy and photon scattering, Nuclear Inst. and Methods in Physics Research, A (2019),
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.