Miniaturized high-performance liquid chromatography instrumentation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
31
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 65 publications
(31 citation statements)
references
References 153 publications
0
31
0
Order By: Relevance
“…Still, the few groups that have been pursuing this have made good demonstration of the potential in working at high pressures. [6][7][8][9][10] In inertial focusing, it is generally accepted that in a straight channel, the migration and equilibrium of particles are mainly due to two forces; the shear gradient lift force, directed towards the walls of the channel and originated from the non-zero curvature of the flow profile, and the wall force, repelling particles from the walls and originated from the interaction of the stresslet around the particle and the wall. Reviews on the phenomenon can be found elsewhere, [11][12][13][14] but an introduction with key points is included in the following paragraphs to ease the understanding of the results and discussion.…”
Section: Introductionmentioning
confidence: 99%
“…Still, the few groups that have been pursuing this have made good demonstration of the potential in working at high pressures. [6][7][8][9][10] In inertial focusing, it is generally accepted that in a straight channel, the migration and equilibrium of particles are mainly due to two forces; the shear gradient lift force, directed towards the walls of the channel and originated from the non-zero curvature of the flow profile, and the wall force, repelling particles from the walls and originated from the interaction of the stresslet around the particle and the wall. Reviews on the phenomenon can be found elsewhere, [11][12][13][14] but an introduction with key points is included in the following paragraphs to ease the understanding of the results and discussion.…”
Section: Introductionmentioning
confidence: 99%
“…Although this effect is marginally reduced by programming the pumps 180° out of phase from one another, pulsations persist. The pump arrangement adopted in Minichrom [55] allows a lower flow rate range for the pump [139]. Low LODs were achieved for phenol (0.2 ppm) and anthracene (0.015 ppm) demonstrating the sensitivity of the system.…”
Section: Tulchinsky St Angelo (1998)mentioning
confidence: 99%
“…Flow rate fluctuations remains the main limitation to the commercialisation of EOP-based portable devices. Variations can arise from unstable voltage sources, and chemical breakdown within the pumping element [139]. Despite this, since EOPs do not contain moving parts, one could expect a degree of resilience to mechanical damage.…”
Section: Ishida Et Al (2015)mentioning
confidence: 99%
“…The flow inside microchannels can be induced in two main methods; one is by using an external pump, such as a syringe pump or an high performance liquid chromatography (HPLC) pump [8], while another is utilizing centrifugal forces in a disc-shaped platform. In such a design, microfluidic features, known as "chambers", contain the sample fluid, while other features, known as "channels", connect different chambers and act as a passage for fluids inside the disc.…”
Section: Introductionmentioning
confidence: 99%