2011
DOI: 10.1016/j.ijms.2010.10.019
|View full text |Cite
|
Sign up to set email alerts
|

Miniature mass spectrometer equipped with electrospray and desorption electrospray ionization for direct analysis of organics from solids and solutions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
50
0
1

Year Published

2012
2012
2023
2023

Publication Types

Select...
9
1

Relationship

2
8

Authors

Journals

citations
Cited by 50 publications
(51 citation statements)
references
References 60 publications
0
50
0
1
Order By: Relevance
“…57 Other environmentally relevant analytes – amines, nitro compounds, and fluorinated compounds as well as other small organics - have been detected using the Mini 10 with a variety of non-ambient ionization techniques (ESI, DESI, electrosonic spray ionization, APCI, and membrane inlet with electron impact). 15,62,253 …”
Section: Practical Applicationsmentioning
confidence: 99%
“…57 Other environmentally relevant analytes – amines, nitro compounds, and fluorinated compounds as well as other small organics - have been detected using the Mini 10 with a variety of non-ambient ionization techniques (ESI, DESI, electrosonic spray ionization, APCI, and membrane inlet with electron impact). 15,62,253 …”
Section: Practical Applicationsmentioning
confidence: 99%
“…The overall instrument uses 65 W average power and weighs G10 kg. The mass analyzer is a rectilinear ion trap (RIT) [50] operating at a frequency of 1 MHz enclosed in a stainless steel manifold of 470 cm 3 volume [51]. As a result of its simplified geometry and pressure tolerance, RITs have several advantages for miniaturization evidenced in previous applications [52].…”
Section: Dapci Ms Using a Miniature Mass Spectrometermentioning
confidence: 99%
“…Although ion transfer could be achieved by increasing the gas flow rate and by utilizing much larger and powerful vacuum pumps, the size and power consumption of the MS instrument will suffer correspondingly. [50][51][52][53] In spite of these advantages, the use of a mechanical switch to control vacuum pressure and ion introduction duration lowers the scan speed, 13,47 stability, robustness of the system, especially when used in some on-site applications involving harsh environments. In a DAPI setup, high gas flow rate and efficient ion transfer are realized by mechanically opening the API for a very short duration (on the scale of milli-seconds).…”
Section: Introductionmentioning
confidence: 99%