1980
DOI: 10.3109/17453678008990837
|View full text |Cite
|
Sign up to set email alerts
|

Migration of the Acetabular Socket After Total hip Replacement Determined by Roentgen Stereophotogrammetry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
11
0
1

Year Published

1982
1982
2006
2006

Publication Types

Select...
5
4

Relationship

3
6

Authors

Journals

citations
Cited by 43 publications
(13 citation statements)
references
References 5 publications
1
11
0
1
Order By: Relevance
“…To achieve precise results by roentgen stereophotogrammetry the skeletal indicators must be widely spread in the bone (Olsson 1975, Baldursson et al 1980. Probst (1980) has developed a qualified method for roentgen stereophotogrammetry of prosthetic components and has also encountered the problem of skeletal indicators being too close to a straight line.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…To achieve precise results by roentgen stereophotogrammetry the skeletal indicators must be widely spread in the bone (Olsson 1975, Baldursson et al 1980. Probst (1980) has developed a qualified method for roentgen stereophotogrammetry of prosthetic components and has also encountered the problem of skeletal indicators being too close to a straight line.…”
Section: Discussionmentioning
confidence: 99%
“…Roentgen stereophotogrammetry offers very high accuracy for the determination of the three-dimensional position of implants in the bone (Selvik 1974). This method has been used in Lund for the determination of migration and wear in THR (Baldursson et al 1979(Baldursson et al , 1980. It can also be used in surface replacement of the hip.…”
mentioning
confidence: 99%
“…A detailed description of the RSA technique has been given by Selvik (1974), Baldursson et al (1979Baldursson et al ( , 1980 and Mogensen et al (1982). The term instability is used for prosthetic component displacement in relation to bone a t distraction-compression and a t rotation (Mjoberg et al 1984 b).…”
Section: Methodsmentioning
confidence: 99%
“…A large compliance would allow the component to change position, for example with every step the patient takes, whereas a low compliance would result in a slow, flow-like migration, corresponding to stress being put on the prosthesis over a long period of time. By using different cementation techniques (Miller 1979) as well as no cement at all (Hungerford et al 1982, Blaha et al 1982, differences in both the development of zones as well as the patterns of movement can be anticipated.…”
Section: 'mentioning
confidence: 99%