2020
DOI: 10.1016/j.arth.2019.10.018
|View full text |Cite
|
Sign up to set email alerts
|

Midterm Outcomes and Frequency of Osteolysis of Total Hip Arthroplasty Using Cementless Modular Stem for Asian Patients

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
1

Year Published

2020
2020
2022
2022

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 34 publications
0
4
1
Order By: Relevance
“…Sato et al reported excellent mid-term fixation of the S-ROM-A prosthesis. All stems showed bone ingrowth in 331 hips [16]. Compared to these previous reports, the present results for stem fixation were worse.…”
Section: Stem Fixationcontrasting
confidence: 86%
See 2 more Smart Citations
“…Sato et al reported excellent mid-term fixation of the S-ROM-A prosthesis. All stems showed bone ingrowth in 331 hips [16]. Compared to these previous reports, the present results for stem fixation were worse.…”
Section: Stem Fixationcontrasting
confidence: 86%
“…Le et al and Biant et al reported that no femoral components were revised with mean follow-up durations of 17 years and 10 years, respectively, using the S-ROM prosthesis [11,12]. Sato et al reported a 10-year femoral component survival rate of 84% for the S-ROM-A prosthesis, and the reason for all revisions was adverse reaction to the metal debris (ARMD) [16]. They used metal on metal, metal on polyethylene, and ceramic on polyethylene bearing surfaces, and the revision rates were 10.3%, 2.5%, and 0% respectively.…”
Section: Femoral Component Survival Rate and Revisionmentioning
confidence: 99%
See 1 more Smart Citation
“…A thin trunnion has been linked to increased risk of trunnionosis [17,18]. Sato et al [5] reported a slightly higher incidence of osteolysis in MoM THA with the S-ROM-A stem than with the original S-ROM stem. In the present study, ARMD due to trunnionosis occurred in 1 (8.3%) of the MoM cases with a 36-mm head.…”
Section: Late Complications Possibly Related To the Design Modificationmentioning
confidence: 99%
“…This study investigated the subsequent mid-to long-term outcomes of the 220 DDH hips, focusing on the following. Firstly, an association has been suggested between the change in trunnion size in the S-ROM-A stem and increased incidence of metal-related complications at the trunnion [5]. We investigated the incidence of these complications and other late complications as well as implant failures, suspected to be related to the design modification.…”
mentioning
confidence: 99%