2017
DOI: 10.1007/s10853-017-1715-0
|View full text |Cite
|
Sign up to set email alerts
|

Microwave synthesis and voltammetric simultaneous determination of paracetamol and caffeine using an MOF-199-based electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
15
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 49 publications
(19 citation statements)
references
References 55 publications
3
15
0
Order By: Relevance
“…A comparison of the proposed method with other voltammetric methods for AA, PA, and CA determination is listed in Table 3. It could be noticed that LOD of AA, PA, and CA from the proposed method is lower or comparable with those results based on modified electrodes in previous papers [47,49,50,[52][53][54][55][56][57][58]. Overall, ErGO is proved to be an effective electrode modifier for the determination of AA, PA, and CA.…”
Section: Effect Of Interferentssupporting
confidence: 80%
“…A comparison of the proposed method with other voltammetric methods for AA, PA, and CA determination is listed in Table 3. It could be noticed that LOD of AA, PA, and CA from the proposed method is lower or comparable with those results based on modified electrodes in previous papers [47,49,50,[52][53][54][55][56][57][58]. Overall, ErGO is proved to be an effective electrode modifier for the determination of AA, PA, and CA.…”
Section: Effect Of Interferentssupporting
confidence: 80%
“…The linear plots of cathodic peak current ( I pc ) against the square root of the scan rate ( v 1/2 ) were drawn to determine whether the electroreductive reaction was controlled by adsorption or diffusion. If the plot of I pc versusv 1/2 is linear and passes the origin, this process is controlled by diffusion [21]. The linear regression equations of I pc ( μ A) for Pb, Cd, and Zn oxidation versusv 1/2 are as as follows:Ipc,Pb=0.7±1.4+7.1±2.6v1/2, r=0.980, Ipc,Cd =0.8±1.2+7.2±2.2v1/2, r=0.986, Ipc,Zn=0.5±1.1+7.3±2.1v1/2, r=0.989.…”
Section: Resultsmentioning
confidence: 99%
“…Due to synergistic effects on the electrochemical performance of devices, nanocomposites can be useful to improve the resolution and the selectivity, especially when multi-analyte detection of close species is desirable. Table 4 [ [19] , [25] , [75] , [76] , [77] , [78] , [79] , [80] , [81] , [82] , [83] , [84] , [85] , [86] , [87] , [88] , [89] , [90] , [91] , [92] , [93] , [94] , [95] , [96] , [97] , [98] , [99] , [100] , [101] , [102] , [103] , [104] , [105] , [106] , [107] , [108] , [109] , [110] , [111] , [112] , [113] , [114] , [115] , [116] , [117] , [118] , [119] , [120] , [121] , [122] , [123] ] shows the analytical response characteristics of PCT sensors based on nanocomposite modified electrodes.…”
Section: Nanocomposites Modifiersmentioning
confidence: 99%
“…Minh et al. [ 119 ] synthesized the MOF-199 using domestic microwave at ambient temperature and pressure. The MOF-199 was simply deposited on the GCE by drop-casting, and then applied for the voltammetric simultaneous determination of PCT and caffeine in pharmaceutical formulations.…”
Section: Nanocomposites Modifiersmentioning
confidence: 99%