2001
DOI: 10.1159/000051585
|View full text |Cite
|
Sign up to set email alerts
|

Microwave Corneosurfametry and the Short-Duration Dansyl Chloride Extraction Test for Rating Concentrated Irritant Surfactants

Abstract: Background: There are ethical concerns to conduct in vivo tests in the animal and human to provide evidence that cosmetics and other topical products are safe. Objective: To compare two methods, namely the short-duration dansyl chloride extraction test and the microwave corneosurfametry bioassay, to test the irritation potential of concentrated surfactant systems. Methods: Five surfactants and water were tested using the in vivo test and the bioassay. Results: A significant linear correlation was found between… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
9
0

Year Published

2003
2003
2015
2015

Publication Types

Select...
5
4

Relationship

1
8

Authors

Journals

citations
Cited by 12 publications
(10 citation statements)
references
References 8 publications
1
9
0
Order By: Relevance
“…However, interpreting the data in terms of 'mature' and 'immature' corneocytes could be challenged. Indeed, the pattern of variations in staining closely resembles the variegation previously reported in the corneosurfametry and corneoxenometry bioassays [6,25,26] and squamometry as well [27,28]. All these methods basically rely on the relative access of dyes to particular binding sites on corneocytes after damaging them.…”
supporting
confidence: 76%
“…However, interpreting the data in terms of 'mature' and 'immature' corneocytes could be challenged. Indeed, the pattern of variations in staining closely resembles the variegation previously reported in the corneosurfametry and corneoxenometry bioassays [6,25,26] and squamometry as well [27,28]. All these methods basically rely on the relative access of dyes to particular binding sites on corneocytes after damaging them.…”
supporting
confidence: 76%
“…The ancillary CSM and its variant microwave CSM are predictive bioassays that have shown their relevance in various experiment studies (11, 13–19, 21,22). These are inexpensive and rapid procedures allowing simultaneous comparisons of many products or concentrations, up to 2 dozen, in a couple of hours.…”
Section: Discussionmentioning
confidence: 99%
“…Microwave CSM is a more rapid procedure than the regular CSM 46. In this procedure, CSSS are immersed in a flask containing the test surfactant solution, and they are placed in a microwave oven containing a 500 mL water load.…”
Section: Analytical Morphology Of Skin Strippingsmentioning
confidence: 99%