2016
DOI: 10.1016/j.bios.2016.06.013
|View full text |Cite
|
Sign up to set email alerts
|

MicroRNA-mediated signal amplification coupled with GNP/dendrimers on a mass-sensitive biosensor and its applications in intracellular microRNA quantification

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
5
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 24 publications
(7 citation statements)
references
References 34 publications
2
5
0
Order By: Relevance
“…Then, another miR‐27a solution and another PBS buffer was alternatively injected again several times but did not bring a significant frequency change. These results indicate that the hybridization of probe miRNA and complementary miR‐27a was effective and easy to be detected by QCM, the frequency change is comparable with those reported QCM sensors …”
Section: Resultssupporting
confidence: 85%
See 3 more Smart Citations
“…Then, another miR‐27a solution and another PBS buffer was alternatively injected again several times but did not bring a significant frequency change. These results indicate that the hybridization of probe miRNA and complementary miR‐27a was effective and easy to be detected by QCM, the frequency change is comparable with those reported QCM sensors …”
Section: Resultssupporting
confidence: 85%
“…Then, another miR-27a solution and another PBS buffer was alternatively injected again several times but did not bring a significant frequency change. These results indicate that the hybridization of probe miRNA and complementary miR-27a was effective and easy to be detected by QCM, the frequency change is comparable with those reported QCM sensors 29,30. For single-base mismatch miR-27b, the frequency was decreased gradually and the frequency change reached to −24 Hz after 5000 seconds when the PBS buffer of 0.5 × 10 −6 M miR-27b was injected into , Schematic diagram of static detection quartz crystal microbalance sensor system.…”
supporting
confidence: 85%
See 2 more Smart Citations
“…The sensing method is to pick up on the frequency shift of QCM (quartz crystal microbalance) sensors (Piezoelectric biosensors concept). c. QCM sensors are compatible with different operating conditions (gaseous or liquid mediums) [26] making it a useful technique in health care. d. Gold-nanoparticles amplify the signal while coupled with an enzymatic amplification process.…”
Section: Recommendationsmentioning
confidence: 99%