2000
DOI: 10.1016/s0925-4005(99)00500-6
|View full text |Cite
|
Sign up to set email alerts
|

Microreactor and electrochemical detectors fabricated using Si and EPON SU-8

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
44
0

Year Published

2004
2004
2012
2012

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 83 publications
(44 citation statements)
references
References 17 publications
0
44
0
Order By: Relevance
“…The intensity of the red luminescence observed on the electrode is measured by an external photodiode. Several groups have already integrated the electrodes and a detecting photodiode, which is easily realized with the present semiconductor technology [54,60,61,[144][145][146]. Furthermore, one of the advantages of micro-electrochemical systems is that the integration of the circuits is possible as an option.…”
Section: Towards Autonomous Microsystemsmentioning
confidence: 99%
“…The intensity of the red luminescence observed on the electrode is measured by an external photodiode. Several groups have already integrated the electrodes and a detecting photodiode, which is easily realized with the present semiconductor technology [54,60,61,[144][145][146]. Furthermore, one of the advantages of micro-electrochemical systems is that the integration of the circuits is possible as an option.…”
Section: Towards Autonomous Microsystemsmentioning
confidence: 99%
“…Immobilized enzymes have been used as component of detection device in various analytical and biomedical applications [19,20,[60][61][62][63] including glucose and penicillin. Some of these devices have been associated with miniaturized electrochemical detectors and fluidic systems.…”
Section: Immobilized Enzyme Biosensorsmentioning
confidence: 99%
“…Some of these devices have been associated with miniaturized electrochemical detectors and fluidic systems. L'Hostis et al [19] tested the enzymatic microreactor for glucose detection via glucose oxidase immobilized to glass beads. Glucose detection was carried out by electrochemical measurements of hydrogen peroxide generated enzymatically with a platinum electrode.…”
Section: Immobilized Enzyme Biosensorsmentioning
confidence: 99%
“…Several bead immobilization approaches have been reported, including mechanical trapping [3][4][5][6], magnetic manipulation [7][8][9][10], and dielectrophoresis (DEP) retention [2,[11][12][13]. For the single-beadbased biochemical assay described in this paper, we immobilized a single bead at the center of a set of trapping electrodes on a microfluidic chip using a negative DEP force.…”
Section: Introductionmentioning
confidence: 99%