Micropumps to support the heart during CABG

Abstract: The supported heart is more resistant to repetitive local ischemia. Support by microaxial pumps can make beating heart surgery safer and applicable for more complex cases.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
14
0
5

Year Published

2002
2002
2010
2010

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 27 publications
(19 citation statements)
references
References 14 publications
0
14
0
5
Order By: Relevance
“…The potential for low-cost mass-production of microfluidic components such as micropumps has appeal for medical, environmental, biotechnology, electronic packaging, space exploration and energy applications where micropumps can be used and dispensed, for example, for drug delivery, sensor measurements, on-chip experiments, DNA replication, micro-propulsion, microelectronic cooling, and fuel delivery (Polla et al 2000;Meyns et al 2000;Gardeniers and van den Berg 2004;Wang and Lee 2005;Bruschi et al 2002;Zhang and Wang 2006). Especially for liquids, overwhelming dominance of viscous forces compared to inertial forces in micro scales limits the implementation of transduction mechanisms in micropumps, which can be, in general, magnetic, electric or mechanical (Laser and Santiago 2004).…”
Section: Introductionmentioning
confidence: 99%
“…The potential for low-cost mass-production of microfluidic components such as micropumps has appeal for medical, environmental, biotechnology, electronic packaging, space exploration and energy applications where micropumps can be used and dispensed, for example, for drug delivery, sensor measurements, on-chip experiments, DNA replication, micro-propulsion, microelectronic cooling, and fuel delivery (Polla et al 2000;Meyns et al 2000;Gardeniers and van den Berg 2004;Wang and Lee 2005;Bruschi et al 2002;Zhang and Wang 2006). Especially for liquids, overwhelming dominance of viscous forces compared to inertial forces in micro scales limits the implementation of transduction mechanisms in micropumps, which can be, in general, magnetic, electric or mechanical (Laser and Santiago 2004).…”
Section: Introductionmentioning
confidence: 99%
“…yap tık la rı hay van ça lış ma sın da, bi ven tri kü ler uy gu la dık la rı Im pel la Mic ro a xi al pom pa la rın mi yo kar dı ko ru ma da ki olum lu et ki leri ni gös ter miş ler dir. 15 Autsc hbach ve ark. çok merkez li ça lış ma la rın da, Im pel la Mic ro a xi al pom pa nın kli nik uy gu la ma la rı nın gü ve nir li ği ve fay da la rın -dan bah set miş ler dir.…”
Section: Tar Tiş Maunclassified
“…Di ğer iki ça lış ma gös te ri yor ki, bu uy gu la ma sı ra sın da mi yo kar di yal ok si jen tü-ke ti mi azalmakta ve mi yo kar di yal per füz yon ile ame li yat son ra sı dö nem de yük sek mi yo kar di yal per for mans sağ lanmaktadır. 15,18 Hay van de ne yi ça-lış ma la rın da, eko kar di yog ra fik bul gu ola rak, atan kalp te bay pas uy gu la ma sı sırasında ve özel lik le Cx ko ro ner ar ter dal la rı na ya pı lan anas to moz iş le mi sı-ra sın da sol ven tri kül do lu şu nun ve bo şal ma sı nın kı sıt lan dı ğı, so nuç ta he mo di na mik ins ta bi li te ye sebe bi yet ver ildi ği gö rül müş tür. 5 Atan kalp te bay pas ame li ya tı sı ra sın da, des tek ci ha zı ola rak sen tri fu gal pom pa lar ve ya mik ro ak si yal akım lı pom pa lar se çi -le bi lir.…”
Section: Tar Tiş Maunclassified
See 1 more Smart Citation
“…9,10 Hemodynamic stabilization during beating-heart myocardial revascularization by an intracardiac implanted blood pump can be achieved in experimental and clinical settings. [11][12][13][14] The Impella Elect 100 blood pump (Impella Cardiosystems, Aachen, Germany) has been developed to avoid hemodynamic instabilities while retracting the heart for exposure.…”
mentioning
confidence: 99%