2017
DOI: 10.3390/polym9100489
|View full text |Cite
|
Sign up to set email alerts
|

Micron-Sized Pored Membranes Based on Polyvinylidene Difluoride Hexafluoropropylene Prepared by Phase Inversion Techniques

Abstract: Abstract:In this study, micron-sized pored membranes, based on the co-polymer polyvinylidene difluoride hexafluoropropylene (PVdF-HFP) were prepared via phase inversion techniques. The aim of the approach was to find less harmful and less toxic solvents to fabricate such films. Therefore, the Hansen solubility approach was used to identify safer and less toxic organic solvents for the phase inversion process, relative to present solvent mixtures, based on acetone, dimethyl formamide, dimethyl acetamide or meth… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2018
2018
2021
2021

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 31 publications
0
2
0
Order By: Relevance
“…While the strength and elongation of other PEGDA cross-linker-based polymer electrolytes without backbone film remained at no more than 1 MPa and 30%, ,, 40-INSPE 1:2­(2.1 MPa and 36.7%), 40-INSPE 1:1­(3.2 MPa and 28.6%), 40-INSPE 2:1­(2.7 MPa and 11.6%), 100-INSPE 1:2­(3.6 MPa and 46.2%), 100-INSPE 1:1­(6.9 MPa and 40.5%), and 100-INSPE 2:1­(6.6 MPa and 24.3%) showed substantially improved values of strength and elongation. Detailed comparison of reference PVDF- co -HFP membrane, reference SPE, ,, and as-fabricated INSPEs in mechanical and electrochemical aspects are shown in the Tables S1 and S2.…”
Section: Resultsmentioning
confidence: 99%
“…While the strength and elongation of other PEGDA cross-linker-based polymer electrolytes without backbone film remained at no more than 1 MPa and 30%, ,, 40-INSPE 1:2­(2.1 MPa and 36.7%), 40-INSPE 1:1­(3.2 MPa and 28.6%), 40-INSPE 2:1­(2.7 MPa and 11.6%), 100-INSPE 1:2­(3.6 MPa and 46.2%), 100-INSPE 1:1­(6.9 MPa and 40.5%), and 100-INSPE 2:1­(6.6 MPa and 24.3%) showed substantially improved values of strength and elongation. Detailed comparison of reference PVDF- co -HFP membrane, reference SPE, ,, and as-fabricated INSPEs in mechanical and electrochemical aspects are shown in the Tables S1 and S2.…”
Section: Resultsmentioning
confidence: 99%
“…The ratio of the volume of n-decane to the volume of the sample gives the porosity of the sample [10,14,40,41].…”
Section: Measurement Of Porosity Of a Nonwoven Samplementioning
confidence: 99%