2020
DOI: 10.1016/j.chroma.2019.460539
|View full text |Cite
|
Sign up to set email alerts
|

Microfluidic platform for rapid screening of bacterial cell lysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
17
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 8 publications
(18 citation statements)
references
References 36 publications
1
17
0
Order By: Relevance
“…It was shown that even a significant increase in the concentration of the lysis reagent does not increase the lysis efficiency of the cell solution. On the other hand, increasing the volume fraction of the lysis reagent (the ratio of the volume initially filled with the lysis reagent to the total volume of the droplet) to 97%, achieved a complete cell solution lysis within 0.25 s. R. Fradique et al reported a diffusion-based microfluidic device for the rapid screening of continuous lysis conditions, utilizing E. coli as a model host [ 18 ]. The main goal of the work was to determine the efficiency of different lysis conditions for the release of an intracellular protein from the bacteria cells, in other words, to measure the effect of different lysis solutions, contact times, and cell to lysis solution volume ratios.…”
Section: Cell Lysis Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…It was shown that even a significant increase in the concentration of the lysis reagent does not increase the lysis efficiency of the cell solution. On the other hand, increasing the volume fraction of the lysis reagent (the ratio of the volume initially filled with the lysis reagent to the total volume of the droplet) to 97%, achieved a complete cell solution lysis within 0.25 s. R. Fradique et al reported a diffusion-based microfluidic device for the rapid screening of continuous lysis conditions, utilizing E. coli as a model host [ 18 ]. The main goal of the work was to determine the efficiency of different lysis conditions for the release of an intracellular protein from the bacteria cells, in other words, to measure the effect of different lysis solutions, contact times, and cell to lysis solution volume ratios.…”
Section: Cell Lysis Methodsmentioning
confidence: 99%
“…diffusion-based microfluidic device for the rapid screening of continuous lysis conditions, utilizing E. coli as a model host [18]. The main goal of the work was to determine the efficiency of different lysis conditions for the release of an intracellular protein from the bacteria cells, in other words, to measure the effect of different lysis solutions, contact times, and cell to lysis solution volume ratios.…”
Section: Chemical Lysismentioning
confidence: 99%
See 3 more Smart Citations