The platform will undergo maintenance on Sep 14 at about 7:45 AM EST and will be unavailable for approximately 2 hours.
2022
DOI: 10.1016/j.aca.2022.339722
|View full text |Cite
|
Sign up to set email alerts
|

Microfluidic aptasensor POC device for determination of whole blood potassium

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7
2

Relationship

1
8

Authors

Journals

citations
Cited by 21 publications
(5 citation statements)
references
References 65 publications
0
5
0
Order By: Relevance
“…range from 0.05 × 10 −3 mol/L to 9 × 10 −3 mol/L and have a limit of detection (LOD) of 0.01 × 10 −3 mol/L. This device demonstrates that low-cost POC microfluidic sensors with on-chip blood separations (serum from whole blood) are attainable [27]. Another example of the capability of these devices is in the separation of extracellular vesicles such as exosomes.…”
Section: Introductionmentioning
confidence: 92%
“…range from 0.05 × 10 −3 mol/L to 9 × 10 −3 mol/L and have a limit of detection (LOD) of 0.01 × 10 −3 mol/L. This device demonstrates that low-cost POC microfluidic sensors with on-chip blood separations (serum from whole blood) are attainable [27]. Another example of the capability of these devices is in the separation of extracellular vesicles such as exosomes.…”
Section: Introductionmentioning
confidence: 92%
“…The integration of microfluidic platforms with disposable paper strips has also been utilized for aptamer-based biomarker detection applications [115][116][117][118][119][120][121]. Recently, a low-cost and smartphone-adapted sensing platform was introduced for measuring potassium ion (K + ) levels in whole blood, which is an essential parameter for chronic kidney disease [58]. In short, the platform comprises PMMA-sealed paper microfluidic chip and finger pumps for transporting different reagents into the reaction chamber.…”
Section: Paper-based Colorimetric Aptasensorsmentioning
confidence: 99%
“…The demand for microflow devices dedicated to automatic detection and quantification of chosen ions is undeniable, and the best example of such is the one developed by Chin-Chung Tseng et al [ 121 ]. This is a typical Point-of-Care device.…”
Section: Microfluidic Aptamer-based Sensors For Ions Detectionmentioning
confidence: 99%
“… ( a ) The example of aptamer biochip to K + detection and the dedicated device for operation, ( b ) Reaction color for different volumes of AuNPs and concentrations of 3 mLNaCl together with reaction color for 8 mL AuNPs, 3 mL NaCl (0.4 M) and different volumes of aptamers [ 121 ]. …”
Section: Figurementioning
confidence: 99%