Our system is currently under heavy load due to increased usage. We're actively working on upgrades to improve performance. Thank you for your patience.
2000
DOI: 10.1016/s0304-3991(99)00145-x
|View full text |Cite
|
Sign up to set email alerts
|

Microcantilever-based biosensors

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

2
114
0

Year Published

2001
2001
2015
2015

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 222 publications
(118 citation statements)
references
References 15 publications
2
114
0
Order By: Relevance
“…The estimation of the magnitude of threshold stress, r0, is done in several ways. The experimental data at a single temperature are generally plotted as e_ 1 n s against r in double linear scales with known values of n [41] (n = 3 for creep controlled by viscous glide processes [32], n = 5 for creep controlled by high temperature climb of dislocations (lattice diffusion) [29,42], n = 7 for creep controlled by low temperature climb (core diffusion) [43] and n = 8 for lattice diffusion controlled creep with a constant structure [44]). If the creep rate of the composite obeys Eq.…”
Section: Evaluation Of Steady State Creep Mechanismmentioning
confidence: 99%
“…The estimation of the magnitude of threshold stress, r0, is done in several ways. The experimental data at a single temperature are generally plotted as e_ 1 n s against r in double linear scales with known values of n [41] (n = 3 for creep controlled by viscous glide processes [32], n = 5 for creep controlled by high temperature climb of dislocations (lattice diffusion) [29,42], n = 7 for creep controlled by low temperature climb (core diffusion) [43] and n = 8 for lattice diffusion controlled creep with a constant structure [44]). If the creep rate of the composite obeys Eq.…”
Section: Evaluation Of Steady State Creep Mechanismmentioning
confidence: 99%
“…Single microcantilevers are generally known to be susceptible to spurious deflections because of temperature changes, chemical interaction of a coated cantilever with the liquid environment, and slow rearrangement of molecules in the protein multilayer (10,12,26,27). As a result, a base-line drift can be observed during static-mode measurements.…”
Section: Resultsmentioning
confidence: 99%
“…When antibodies or small DNA fragments were immobilized on one side of a cantilever, the presence of complementary biological species produced cantilever deflections in a rather predictable manner (9,(15)(16)(17). On the basis of the deflection behavior of MCs modified with biological receptors, even very small mismatches in receptor-analyte complementarity could be detected.…”
Section: Applicationsmentioning
confidence: 91%
“…An increasing number of recent reports confirms the potential of MC sensors for environmental and biomedical applications, and the multifaceted functionality of MCs indicates their uniqueness as compared with more traditional sensor designs (7)(8)(9)(10)(11)(12)(13)(14)(15)(16)(17).…”
mentioning
confidence: 99%