2021
DOI: 10.3897/bdj.9.e71542
|View full text |Cite
|
Sign up to set email alerts
|

Micro-CT protocols for scanning and 3D analysis of Hexaplex trunculus during its different life stages

Abstract: Micro-computed tomography (micro-CT) is a high-resolution 3D-imaging technique which is now increasingly applied in biological studies focusing on taxonomy and functional morphology. The creation of virtual representations of specimens can increase availability of otherwise underexploited and inaccessible samples. The 3D model dataset can be also further processed through volume rendering and morphometric analysis. The success of micro-CT as a visualisation technique depends on several methodological manipulat… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
2
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 16 publications
(22 reference statements)
0
2
0
Order By: Relevance
“…Approximately 700 micro-CT images were generated and analyzed using a CT Analyser. 56 The variables such as bone mineral density (BMD), trabecular bone volume to total volume fraction (BV/TV), trabecular thickness (Tb.Th), trabecular number (Tb.N), and trabecular separation (Tb.Sp) were measured and evaluated to compare between groups (control, collagen, GO-PLA, and PLA).…”
Section: Methodsmentioning
confidence: 99%
“…Approximately 700 micro-CT images were generated and analyzed using a CT Analyser. 56 The variables such as bone mineral density (BMD), trabecular bone volume to total volume fraction (BV/TV), trabecular thickness (Tb.Th), trabecular number (Tb.N), and trabecular separation (Tb.Sp) were measured and evaluated to compare between groups (control, collagen, GO-PLA, and PLA).…”
Section: Methodsmentioning
confidence: 99%
“…Micro-CT parameters and indicators: The scanning voltage is 80 kV, the electric current is 500μA, and the scanning resolution is 10.44μm. After scanning, mimics software was used for 3D reconstruction with voxels of 1024μm×1024μm×1024μm [ 20 ]. The detection parameters include tissue volume (TV, Tissue Volume), bone volume (BV, Bone Volume); the Connection Density (Connectivity Density, Conn.D.…”
Section: Methodsmentioning
confidence: 99%
“…Micro-CT parameters and indicators: The scanning voltage is 80 kV, the electric current is 500μA, and the scanning resolution is 10.44μm. After scanning, mimics software was used for 3D reconstruction with voxels of 1024μm×1024μm×1024μm [20].…”
Section: Micro-ct Analysismentioning
confidence: 99%