2021
DOI: 10.1093/chromsci/bmab122
|View full text |Cite
|
Sign up to set email alerts
|

Method Validation and Rapid Determination of Monosodium Glutamate in Various Food Products by HPLC–Fluorescence Detection and Method Optimization of HPLC–Evaporative Light Scattering Detection Approach without Derivatization

Abstract: In this study, an effective, simple and rapid high-performance liquid chromatography (HPLC) using fluorescence (FLD) method was developed and validated for the determination of monosodium glutamate (MSG) in 57 various food samples. Besides, HPLC-Evaporate Light Scattering Detection (ELSD) method was carried out for determination of MSG without derivatization. MSG analysis was performed by derivatization with dansyl chloride at excitation 328, emission 530nm with fluorescence detector. HPLC-FLD method was carri… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 29 publications
0
3
0
Order By: Relevance
“…The MSG and IMP contents in soy sauce were detected by HPLC. For HPLC detection of MSG, soy sauce was diluted at a 1:400 ratio with ultrapure water and homogenized using a vortex mixer. , For IMP determination, each 5 mL of soy sauce sample (accurate to 0.1 mL) was taken in a 50 mL volumetric flask, and methanol (HPLC grade) was added to the solution for precipitation for 30 min. After centrifugation at 10 000 rpm for 15 min, 5 mL of the supernatant was accurately drawn with a pipet, diluted with ultrapure water to 10 mL, and passed through an activated C18 solid-phase extraction column (Bkmam, China) to collect the intermediate filtrate of about 5 mL, which was then filtered through a 0.22 μm membrane.…”
Section: Methodsmentioning
confidence: 99%
“…The MSG and IMP contents in soy sauce were detected by HPLC. For HPLC detection of MSG, soy sauce was diluted at a 1:400 ratio with ultrapure water and homogenized using a vortex mixer. , For IMP determination, each 5 mL of soy sauce sample (accurate to 0.1 mL) was taken in a 50 mL volumetric flask, and methanol (HPLC grade) was added to the solution for precipitation for 30 min. After centrifugation at 10 000 rpm for 15 min, 5 mL of the supernatant was accurately drawn with a pipet, diluted with ultrapure water to 10 mL, and passed through an activated C18 solid-phase extraction column (Bkmam, China) to collect the intermediate filtrate of about 5 mL, which was then filtered through a 0.22 μm membrane.…”
Section: Methodsmentioning
confidence: 99%
“…Several methods were reported for determination of MSG, including UV/visible spectrophotometry [10,[19][20][21][22][23], spectroflourometry [24][25][26], and electrochemistry [27][28][29][30]. Other methods were reported for separation of MSG including capillary electrophoresis [31], paper chromatography [32], thin layer chromatography [33], LC-MS/MS [34] and HPLC with UV detection [35,36], fluorescence detection [37] and evaporative light scattering detection [38]. Because MSG lacks a fluorophore, derivatization reaction is required for its determination, but these reactions need expensive reagents and specified conditions such as prolonged reaction time, heat, and catalysis.…”
Section: Introductionmentioning
confidence: 99%
“…There are many researchers from various disciplines who have conducted research in the field of testing MSG in food: Monošík et al [17] investigated the analysis technique using chromatography for the determination of L-glutamate in food samples, analysis technique using fluorescence by Soyseven and Arli [18], capillary electrophoresis [19],…”
Section: Introductionmentioning
confidence: 99%