Method validation and comparison of quantification strategies for analysis of chlorinated paraffins in indoor dust by liquid chromatography and high-resolution mass spectrometry

Abstract: This paper describes the validation of a method for the simultaneous analysis of short-, medium-, and long-chained chlorinated paraffins (SCCPs, MCCPs, and LCCPs, respectively) in indoor dust by ultrasonic extraction and liquid chromatography quadrupole time-of-flight high-resolution mass spectrometry (LC-QTOF-HRMS). A series of spike and recovery experiments (n = 54) were conducted using CPs with varying carbon-chain lengths, chlorination degree, and concentrations. Technical standard mixtures of the SCCPs, M… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
7
1

Year Published

2022
2022
2024
2024

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(9 citation statements)
references
References 31 publications
1
7
1
Order By: Relevance
“…CP analysis was performed on an Agilent 1290 Infinity II LC coupled to an Agilent 6560 QTOF-MS with electrospray ionization (ESI) operated in negative mode according to methods described by McGrath et al (2022). Partial separation of CP homologues was achieved by 5 µL injections to an Agilent Zorbax Eclipse Plus C18 Rapid Resolution HD column (2.1 × 50 mm, 1.8 µm pore size) fitted with a matched 5 mm length guard column maintained at a temperature of 40 C. The mobile phase consisted of (A) Milli-Q water and (B) methanol containing 25 µM ammonium chloride with a constant flow rate of 0.2 mL/min.…”
Section: Analysis and Quantificationmentioning
confidence: 99%
See 4 more Smart Citations
“…CP analysis was performed on an Agilent 1290 Infinity II LC coupled to an Agilent 6560 QTOF-MS with electrospray ionization (ESI) operated in negative mode according to methods described by McGrath et al (2022). Partial separation of CP homologues was achieved by 5 µL injections to an Agilent Zorbax Eclipse Plus C18 Rapid Resolution HD column (2.1 × 50 mm, 1.8 µm pore size) fitted with a matched 5 mm length guard column maintained at a temperature of 40 C. The mobile phase consisted of (A) Milli-Q water and (B) methanol containing 25 µM ammonium chloride with a constant flow rate of 0.2 mL/min.…”
Section: Analysis and Quantificationmentioning
confidence: 99%
“…Limits of quantification (LOQs) were defined as the lowest ∑ SCCP, ∑ MCCP, and ∑ LCCPs (C 18-20 ) concentration at which at least half of the congener groups were detected in both the lowest and highest Cl% standard mixtures, equating to the equivalent of 200, 100, and 100 ng/g in dust, respectively. The LOQ derivation is described in detail by McGrath et al (2022).…”