2024
DOI: 10.1016/j.chemosphere.2024.141401
|View full text |Cite
|
Sign up to set email alerts
|

Quantification of chlorinated paraffins by chromatography coupled to high-resolution mass spectrometry – Part B: Influence of liquid chromatography separation

Cherine Amoura,
Frédéric Larvor,
Philippe Marchand
et al.
Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
0
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 52 publications
0
0
0
Order By: Relevance
“…Due to similar polarities of carbon- and chlorine-homologues of CPs, these coelute in a wide retention time window . As a consequence of the large number of stereoisomers present in CP mixtures, broad chromatographic peaks of 2–3 min are often expected. This complicates the data processing based on the chromatographic peak area. In addition, instrumentation with high resolution is beneficial for CP analysis; therefore, quadrupole time-of-flight or Orbitrap mass analyzers are preferably used. , Under respective chromatographic conditions, the ESI source generates [M + Cl] − , [M – H] − or [M + acetate] − ions, whereas the APCI source generates [M + Cl] − ions. This results in complex mass spectra, which can contain more than 1400 target compounds.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Due to similar polarities of carbon- and chlorine-homologues of CPs, these coelute in a wide retention time window . As a consequence of the large number of stereoisomers present in CP mixtures, broad chromatographic peaks of 2–3 min are often expected. This complicates the data processing based on the chromatographic peak area. In addition, instrumentation with high resolution is beneficial for CP analysis; therefore, quadrupole time-of-flight or Orbitrap mass analyzers are preferably used. , Under respective chromatographic conditions, the ESI source generates [M + Cl] − , [M – H] − or [M + acetate] − ions, whereas the APCI source generates [M + Cl] − ions. This results in complex mass spectra, which can contain more than 1400 target compounds.…”
Section: Introductionmentioning
confidence: 99%
“… 10 As a consequence of the large number of stereoisomers present in CP mixtures, broad chromatographic peaks of 2–3 min are often expected. 10 12 This complicates the data processing based on the chromatographic peak area. In addition, instrumentation with high resolution is beneficial for CP analysis; therefore, quadrupole time-of-flight or Orbitrap mass analyzers are preferably used.…”
Section: Introductionmentioning
confidence: 99%