Method for continuous nondisturbing monitoring of blood pressure by magnetoelastic skin curvature sensor and ECG

Abstract: This paper concerns continuous nondisturbing estimation of blood pressure using mechanical plethysmography in connection with standard electrocardiography (ECG). The plethysmography is given by a novel magnetoelastic skin curvature sensor (SC-sensor) applied on the neck over the carotid artery. The sensor consists of a magnetoelastic bilayer partly enclosed by a coil. Bending the bilayer causes large changes of magnetic permeability which can be measured by the coil. The SC-sensor signal and the ECG signal are… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
36
0

Year Published

2009
2009
2019
2019

Publication Types

Select...
4
3
1

Relationship

1
7

Authors

Journals

citations
Cited by 72 publications
(36 citation statements)
references
References 14 publications
0
36
0
Order By: Relevance
“…However, in many available results, a single PTT and a model with different model parameters are used to estimate SBP and DBP. 16,22,28 In this way, the model parameters are changing at a fast rate when BP changes significantly and rapidly. Consequently, intermittent recalibration using external device is inevitable.…”
Section: Discussionmentioning
confidence: 99%
“…However, in many available results, a single PTT and a model with different model parameters are used to estimate SBP and DBP. 16,22,28 In this way, the model parameters are changing at a fast rate when BP changes significantly and rapidly. Consequently, intermittent recalibration using external device is inevitable.…”
Section: Discussionmentioning
confidence: 99%
“…The model coefficients are identified by individual calibration. 1,3,4,6,7,[9][10][11][12]15 Theoretical modeling of the relationship between BP and PTT/PWV is a crucial part in the methodology above. So far, the proposed theoretical models fall into two categories: linear models and nonlinear models.…”
Section: Current Status Of Bp Measurement Based On Pwvmentioning
confidence: 99%
“…3 Some researchers considered the nonlinearity of the elastic property of the vascular wall and established two typical non-linear models. 4,6,[9][10][11] …”
Section: Current Status Of Bp Measurement Based On Pwvmentioning
confidence: 99%
See 1 more Smart Citation
“…The polymer PDMS enables the creation of a membrane with extremely low stiffness coefficient, which exhibits large deflection when subject to pressure. The amorphous magnetic alloy Vitrovac® has been utilized for various sensing applications before [9][10][11][12] owing to its soft magnetic properties. It possesses extremely high magnetic permeability [13] and increases the variation of magnetic flux density in the vicinity of the planar coils, due to the deflection of the membrane.…”
Section: Introductionmentioning
confidence: 99%