2022
DOI: 10.1002/elps.202200144
|View full text |Cite
|
Sign up to set email alerts
|

Method development for quantitative monitoring of monoclonal antibodies in upstream cell‐culture process samples with limited sample preparation – An evaluation of various capillary coatings

Abstract: Monoclonal antibodies (mAbs) have become an important class of biopharmaceuticals used for the treatment of various diseases. Their quantification during the manufacturing process is important. In this work, a capillary zone electrophoresis (CZE) method was developed for the monitoring of the mAb concentration during cell‐culture processes. CZE method development rules are outlined, particularly discussing various capillary coatings, such as a neutral covalent polyvinyl alcohol coating, a dynamic successive mu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
9
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 7 publications
(10 citation statements)
references
References 29 publications
(33 reference statements)
0
9
0
Order By: Relevance
“…There are a number of variants of both methods [170,191,193,195]. Those may be optimized for a specific mAb (see Section 9.1.1) [196].…”
Section: Czementioning
confidence: 99%
See 3 more Smart Citations
“…There are a number of variants of both methods [170,191,193,195]. Those may be optimized for a specific mAb (see Section 9.1.1) [196].…”
Section: Czementioning
confidence: 99%
“…(I) T-EthA method for the concentration determination of mAb (in example process samples) [193] Polyvinyl alcohol (PVA)-coated capillaries with 50-µm id, a total length of 33 cm with an effective length of 24.5 or 8.5 cm (e.g., Agilent Technologies) Separation voltage: 16 kV, ramped over 0.5 min (approx. 45 µA) Sample injection at 10 mbar for 5 s, followed by the injection of a BGE plug using the same conditions T = 20 The intra-day precision and accuracy were 2%-12% and 88%-107%, respectively, and inter-day precision and accuracy were 4%-9% and 93%-104%, respectively t ana = 6-11 min (II) eACA method for the charge heterogeneity determination in drug substance and drug product [170] The BGE comprising 400 mM eACA and 2.0 mM.…”
Section: Cief and Iciefmentioning
confidence: 99%
See 2 more Smart Citations
“…The use of a bare fused silica capillary can also be responsible for the loss in electrophoretic resolution based on adsorption effects on the capillary wall [11]. This can be solved by using dynamic coatings with, for example, triethanolamine [12] or TETA [13] as BGE additive or by using neutral coated capillaries [12]. These types of amines could dynamically coat the capillary wall and/or act as cationic ion pairing reagents with acidic functional groups on the protein [13].…”
Section: Introductionmentioning
confidence: 99%