1977
DOI: 10.2106/00004623-197759070-00004
|View full text |Cite
|
Sign up to set email alerts
|

Metal sensitivity before and after total hip arthroplasty

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
59
1
1

Year Published

1980
1980
2016
2016

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 166 publications
(62 citation statements)
references
References 0 publications
1
59
1
1
Order By: Relevance
“…The guinea pig has classically been the animal of choice for modeling human allergy and has been studied quite thoroughly as an excellent model for chromium hypersensitivity and contact dermatitis (Polak et al 1973). However, it would appear that the guinea pig can be sensitized to nickel only with great difficulty if at all (Turk & Parker 1977). Furthermore, the guinea pig has not served as a model for orthopedic surgery.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The guinea pig has classically been the animal of choice for modeling human allergy and has been studied quite thoroughly as an excellent model for chromium hypersensitivity and contact dermatitis (Polak et al 1973). However, it would appear that the guinea pig can be sensitized to nickel only with great difficulty if at all (Turk & Parker 1977). Furthermore, the guinea pig has not served as a model for orthopedic surgery.…”
Section: Discussionmentioning
confidence: 99%
“…However, the contribution of this metal sensitivity to such complications is still con-0001-6470/80/030403-09$02.50/0 troversial; whether or not and for how long sensitive individuals can accept metal appliances is still open to question. Some claim there is no problem (Fisher 1973(Fisher , 1977, while others will deviate from their usual implant material selection so as to avoid implanting appliances with one or more metal alloy constituents to which the patient is sensitive (Deutman et al 1977). Certainly sensitivity is not the cause of all problems, although in some cases it may be a major factor.…”
mentioning
confidence: 99%
“…In a study involving 50 patients, the prevalence of metal sensitivity in patients with unexplained loosening of implants was 73.7%, which is significantly higher than 14.8% in those with stable implants [47]. Other small studies support this association [42,48]. On the other hand, Brown et al [49] studied patients (n=20) with sterile, loose MoM McKee-Farrar hip replacements and found that none had positive patch test results and that the biopsy specimen from the surrounding tissue in the 17 patients who had revision surgery showed no histological evidence of metal hypersensitivity [49].…”
Section: Orthopedic Implantsmentioning
confidence: 95%
“…1,3,4,8,12,13,16,44,45 Polymers provide a low-friction surface for articulation as well as some degree of "shock absorption." 67 Metals provide a base of support for the polymer surfaces as well as a surface for fixation to bone to be done.…”
Section: Biomaterials Used In Joint Replacementmentioning
confidence: 99%
“…When this degradative process is severe enough it can damage the structural integrity of the implant, and corrosion products are potentially toxic. 1,[5][6][7]9,14,16,18,24,33,37,46,49,50,56,57,[59][60][61][62][63][64]70 Disc replacement designs incorporate cobalt-chromium-molybdenum alloy endplates that are externally coated with titanium for bone ingrowth. The metallic endplates are fixed to polymeric cores and motion takes place between articulating polymer surfaces.…”
Section: Biomaterials Used In Joint Replacementmentioning
confidence: 99%