2021
DOI: 10.1016/j.molliq.2021.116801
|View full text |Cite
|
Sign up to set email alerts
|

Mesoporous metal organic frameworks functionalized with the amino acids as advanced sorbents for the removal of bacterial endotoxins from water: Optimization, regression and kinetic models

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
8
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 20 publications
(9 citation statements)
references
References 63 publications
1
8
0
Order By: Relevance
“…coli were best fitted to Freundlich linear and nonlinear models shown in Figure a–f, which corresponded to the higher R 2 values of the Freundlich model than the Langmuir model shown in Table . Literature review shows that other studies also found the same results as this study, that is, the results of the adsorption linear model agreed to those of the nonlinear model, and the equilibrium isotherm parameters of both linear and nonlinear models had close values. As a result, both linear and nonlinear adsorption models are necessary to plot and calculate all isotherm parameters for confirming which adsorption model is the best-fit model to the actual experiment values to avoid errors. , …”
Section: Resultssupporting
confidence: 80%
“…coli were best fitted to Freundlich linear and nonlinear models shown in Figure a–f, which corresponded to the higher R 2 values of the Freundlich model than the Langmuir model shown in Table . Literature review shows that other studies also found the same results as this study, that is, the results of the adsorption linear model agreed to those of the nonlinear model, and the equilibrium isotherm parameters of both linear and nonlinear models had close values. As a result, both linear and nonlinear adsorption models are necessary to plot and calculate all isotherm parameters for confirming which adsorption model is the best-fit model to the actual experiment values to avoid errors. , …”
Section: Resultssupporting
confidence: 80%
“…A heterogeneous surface with adsorption sites with the same bond energy is studied in the Temkin isotherm model. A linear reduction in adsorption heat occurs in this isotherm due to the contact effects of the adsorbent and adsorbate on each other 31 . The following equation expresses the non-linear Temkin models: B is the isotherm constant (J/mol).…”
Section: Methodsmentioning
confidence: 99%
“…Adsorption is not monolayer in the Freundlich isotherm, which is formulated for equilibrium on inhomogeneous surfaces 31 .…”
Section: Methodsmentioning
confidence: 99%
“…Zero-point charges (pH pzc ) were determined by the pH drift method . SG-PEI (5 mg) was added to 20 mL 0.01 M NaCl solution, which has been adjusted to pH values of 3 to 9.…”
Section: Methodsmentioning
confidence: 99%