Mesh terminology 101

Abstract: In any collaborative endeavor, when fields like medicine and bioengineering overlap, the proper use of technical vocabulary takes on added importance. It is important that scientists and clinicians, while coming from different backgrounds and educational systems, agree upon and utilize a common language based on mutually understood concepts and definitions. Regarding biomaterial testing applications, numerous terms are used to describe a wide variety of material behaviors when test specimens are subjected to m… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
51
0
4

Year Published

2010
2010
2022
2022

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 69 publications
(57 citation statements)
references
References 5 publications
1
51
0
4
Order By: Relevance
“…Porosity has been identified to be decisive for proper tissue integration. 9,10 In small pores, the foreign body reaction bridges from one filament to the other and leads to pores completely filled with scar, whereas in structures with sufficiently large pores local physiologically regenerated tissue, for example, fat can be seen. Large pores with a diameter of more than 1000 mm for polypropylene or 600 mm for polyvinyl fluoride have been found to prevent the undesirable bridging of scar tissue throughout the pore.…”
Section: Discussionmentioning
confidence: 99%
“…Porosity has been identified to be decisive for proper tissue integration. 9,10 In small pores, the foreign body reaction bridges from one filament to the other and leads to pores completely filled with scar, whereas in structures with sufficiently large pores local physiologically regenerated tissue, for example, fat can be seen. Large pores with a diameter of more than 1000 mm for polypropylene or 600 mm for polyvinyl fluoride have been found to prevent the undesirable bridging of scar tissue throughout the pore.…”
Section: Discussionmentioning
confidence: 99%
“…The polyethylene graft was first used by Dr. Francis Usher in 1958 (2,3). However, in this first use, sterilization problems were recorded for this material.…”
Section: Resultsmentioning
confidence: 99%
“…Előfordul, hogy a megfelelő porozitású háló fertőződését, sipolyozását a rögzítésére használt polyphil varróanyag okozza. 13 …”
Section: Háló Okozta Szövődményekunclassified
“…De ha a háló -irritációja révén -a bélfalon fejti ki hatását, ami a háló műtéti típushoz nem igazodó kivá-lasztása vagy rossz elhelyezése következtében fordulhat elő, a nemkívánatos kitapadások, hegesedések, megtöreté-sek passage-zavart, sőt ileust okozhatnak. 13 …”
Section: Béladhaesiók Posztoperatív Ileusunclassified