Medium voltage therapy for preventing and treating asystole and PEA in ICDs

Abstract: The inclusion of MVT technology in implantable devices may be effective in preparing the heart for successful defibrillation or in improving the metabolic condition of the heart to the extent that a pulsatile rhythm may spontaneously develop.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2013
2013
2019
2019

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 12 publications
0
5
0
Order By: Relevance
“…Two different pulse train protocols have been tested: a very short pulse width of 0.15 milliseconds delivered at 14 pulses per train and a long pulse width of 7.5 milliseconds at 7 pulses per train to induce thoracic (skeletal) and myocardial muscle contractions. 48 In a large-animal model of VF, both skeletal-based and cardiac-based medium-voltage electric therapy significantly increased the coronary perfusion pressure compared with control, which was comparable to that generated by manual chest compression. Among different stimulation parameters, increasing the pulse train width from 50 to 200 milliseconds and the train rate from 60 to 120 trains per minute further improved the efficacy of medium-voltage electric therapy.…”
Section: Medium-voltage Electric Therapy For Peamentioning
confidence: 83%
“…Two different pulse train protocols have been tested: a very short pulse width of 0.15 milliseconds delivered at 14 pulses per train and a long pulse width of 7.5 milliseconds at 7 pulses per train to induce thoracic (skeletal) and myocardial muscle contractions. 48 In a large-animal model of VF, both skeletal-based and cardiac-based medium-voltage electric therapy significantly increased the coronary perfusion pressure compared with control, which was comparable to that generated by manual chest compression. Among different stimulation parameters, increasing the pulse train width from 50 to 200 milliseconds and the train rate from 60 to 120 trains per minute further improved the efficacy of medium-voltage electric therapy.…”
Section: Medium-voltage Electric Therapy For Peamentioning
confidence: 83%
“…Chest compression and epinephrine are effective for PEA, whereas electrical defibrillation is not. Medium voltage therapy (MVT) has recently been attempted, where electrical stimulation by a cardiac device during ventricular fibrillation or PEA induces skeletal muscle contractions and maintains coronary blood flow in the same manner as chest compression [14,15]. Although this technique has not yet been put to practical use, it would appear to be well suited to cases such as the present one.…”
Section: Discussionmentioning
confidence: 99%
“…However, chest compression devices are controversial and may cause visceral damage (40). Other emerging solutions include electrical stimulation to activate chest wall muscles (41), and simplified methods for cardiopulmonary bypass or extracorporeal circulation.…”
Section: Respondmentioning
confidence: 99%