2010
DOI: 10.1016/j.progsurf.2010.07.003
|View full text |Cite
|
Sign up to set email alerts
|

Mechanics of soft interfaces studied with displacement-controlled scanning force microscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
26
0

Year Published

2010
2010
2022
2022

Publication Types

Select...
6
3
1

Relationship

0
10

Authors

Journals

citations
Cited by 23 publications
(28 citation statements)
references
References 247 publications
2
26
0
Order By: Relevance
“…The twin saturated alkyl tails of DSPC molecule and the polar phosphatidylcholine headgroup are connected each other through a glycerol linker [ 20 ], which constitute the long hydrophobic alkyl tails and the hydrophilic headgroup. Langmuir–Blodgett (LB) [ 21 ] technique was used to prepare the phospholipid films, and AFM was used to characterize these obtained LB films.…”
Section: Experimental Sectionsmentioning
confidence: 99%
“…The twin saturated alkyl tails of DSPC molecule and the polar phosphatidylcholine headgroup are connected each other through a glycerol linker [ 20 ], which constitute the long hydrophobic alkyl tails and the hydrophilic headgroup. Langmuir–Blodgett (LB) [ 21 ] technique was used to prepare the phospholipid films, and AFM was used to characterize these obtained LB films.…”
Section: Experimental Sectionsmentioning
confidence: 99%
“…34 Applying forces at the end of the cantilever also enables more accurate measurement of the tip displacement because one does not need to account for the displacement of the base of the cantilever, as in piezoacoustic excitation. This is particularly important when shaking the cantilever well below or above its resonance frequency, where the motion of the cantilever base induced by piezoacoustic excitation can be comparable to or larger than the motion of the tip.…”
Section: Discussionmentioning
confidence: 99%
“…The characterization of Au probes used in earlier IFM experiments [8] was not reported. IFM probes are not generally believed to wear as much as AFM tips used for imaging, for which even relatively hard silicon nitride tips are known to wear significantly over typical durations of use [24,265]. Kunert, et al [319] recently used lattice Boltzmann simulations to show that during fluid drainage between a spherical probe and a randomly rough surface, the effect of the roughness was to shift the no-slip plane (boundary) of the rough surface to a position between the lowest and farthest extending point.…”
Section: Molecular Shape Of Probe and Substratementioning
confidence: 99%