2010
DOI: 10.1016/j.jcrc.2009.11.010
|View full text |Cite
|
Sign up to set email alerts
|

Mechanical ventilation mode (volume × pressure) does not change the variables obtained by indirect calorimetry in critically ill patients

Abstract: Ventilators and ventilation modes do not influence the IC measurements. The observed changes have no clinical effects and are reversible, provided that increased Vm is maintained for no longer than 45 minutes.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
8
0

Year Published

2013
2013
2023
2023

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 17 publications
(8 citation statements)
references
References 27 publications
0
8
0
Order By: Relevance
“…Finally, the ventilation mode was not recorded at the time of assessment, because this parameter does not affect indirect calorimetry variables in critically ill patients. 33 …”
Section: Discussionmentioning
confidence: 99%
“…Finally, the ventilation mode was not recorded at the time of assessment, because this parameter does not affect indirect calorimetry variables in critically ill patients. 33 …”
Section: Discussionmentioning
confidence: 99%
“…[75][76][77] The volume-controlled ventilator mode has been considered the ideal setting, because it results in less variation in minute ventilation (Ve), which alters gas balance. 77,78 Spontaneous breath settings such as CPAP cause instability and, therefore, may not appropriate for IC testing. 78 While often assumed that a control mode is the only ventilatory setting appropriate for an IC study, other settings may be considered as well.…”
mentioning
confidence: 99%
“…77,78 Spontaneous breath settings such as CPAP cause instability and, therefore, may not appropriate for IC testing. 78 While often assumed that a control mode is the only ventilatory setting appropriate for an IC study, other settings may be considered as well. A mixed-mode setting such as synchronized intermittent mandatory ventilation (SIMV) may be considered for IC testing, although used with caution.…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…Researchers have studied oxygen consumption (VO 2 ) and energy expenditure (EE) in mechanically ventilated patients. It was assessed how the variables VO 2 and EE change upon alterations in mechanical ventilation parameters and modes [ 12 , 13 ], weaning from mechanical ventilation [ 14 , 15 ], physiotherapy [ 16 ], and nutritional therapy [ 17-19 ]. Therefore, VO 2 and EE constitute gold standard in this field.…”
Section: Introductionmentioning
confidence: 99%